Kathrein CAP 600 manual Measures for fire fighting, Measures if inadvertently released

Page 36

SIKAFLEX® 291 SAFETY DATA SHEET

5. Measures for fire fighting

Suitable extinguishing media

Compatible with all extinguishing media in general use. Special hazard from the product, its products of combustion or gases released

In case of fire the following can be released: Carbon monoxide (CO) Carbon dioxide (CO2) Hydrogen chloride (HCl) Oxides of nitrogen (NOx)

Additional instructions

Combustion residues and contaminated extinguishing media must be disposed of in accordance with the local authority regulations. Collect contaminated extinguishing water separately, do not allow it to run into the drains.

6. Measures if inadvertently released

Personal precautions

Ensure sufficient ventilation. Wear protective clothing.

Where vapours/dust/aerosols are present, wear a breathing mask. Environmental protection measures

Do not allow to run into the drains or bodies of water.

In the event of penetration into water, ground or drains, inform the responsible authorities!

Procedure for cleaning/clearing up

Absorb with media that bind to liquids (e.g. sand, sawdust, universal binding media. Dispose of the material that has been cleared up in accordance with the chapter on Disposal.

7. Handling and storage

Handling

Instructions for safe handling:

Refer to Chapter 8 / Personal protective

 

equipment.

Instructions for fire and explosion prevention: Not applicable

Storage

Requirements for storerooms and containers:

Containers should be dry, kept tightly sealed and stored in a cool, well ventilated place. Storage proximity instructions

Store separately from all kinds of foodstuffs. Additional instructions for storage

Protect against frost.

Protect against heat and direct sunlight.

Protect against atmospheric humidity and water.

* 8. Exposure limitation and personal protective equipment

Components subject to monitoring of workplace concentration limits

 

 

Designation of the component

 

 

CAS no.

type

 

Reference/country/year

Naphtha (crude oil), hydro-desulphurised heavy

 

 

64742-82-1

Permissible workplace concentration

350 mg/m3

TRGS 900/DE/2004

64742-82-1

Permissible workplace concentration

70 ml/m3

TRGS 900/DE/2004

36

*) Markings (*) in the left margin indicate revisions from the previous version.

Image 36
Contents CAP Contents Foreign Language Installation MANUAL/DISPOSAL Disposal InstructionsUsed batteries are special waste Mobiset 2 CAP 600 COMPONENTS/SCOPE of Delivery Product PackageProper USE Proper USE USE for the Intended PurposeSafety Instructions Important Notes Fundamental informationAdhesive sealant Power supply, fusing Road Traffic Licensing Regulations StVZOChecks before commencing a journey Installation and Connection Selecting the Installation LocationRequired Tools and Equipment Unpacking and PreparationDirection of travel Installation Steps Installation and Connection Installation and Connection Installation of Turntable Figure E Version with External Cable Gland FIG. F Brief Instructions for Installing the Turntable Tightening torque 6 Nm Suspended Installation Installation on a Fixed Flat Surface Reversal is not possible unit will not function Installation and Connection Connection Example for 12 V Battery Connection Reception RANGE/FOOTPRINT Address of the Service Centre Dismantling for ServicingESC DismantlingPolarisation Setting Polarisation SettingSafety Notes Installation Process On the TurntableView after installation +15 Middle standardManual Lowering to Park Position Manual Lowering Technical Data Dimensions MMTechnical Data Type CAP LNBSikaflex 291 Safety Data Sheet Materials/preparation and company designationComposition/data on components Potential hazardsMeasures for fire fighting Measures if inadvertently releasedHandling and storage Exposure limitation and personal protective equipmentPhysical and chemical characteristics Stability and reactivityToxicology data Sensitisation Ecological dataDisposal instructions Transport dataOther data Sikaflex 291 Technical Data Sheet Sikaflex-291 AflexChemical Stability CAP 600 Operating Manual Important Information for CAP 600 Before Setup Remote ControlFirst Installation Picture format TV-SCART-OutputSystem Local time offsetAlignment Satellite Search Manual Correction Channel Satellite Selection Channel Selection from the Channel ListChange of LOCATION/TIMER Programming Timer ProgrammingRESET/PARKING Resetting the Motorised AntennaParking the Turntable Special Messages from the Turntable System Protection MessagesSpecial Messages from the Turntable Messages Arising from Software Problems Further Messages Declaration of Conformity EC Declaration of ConformityFor Your Notes For Your Notes 936.3220/-/0907/ZWT Technical data subject to change
Related manuals
Manual 1 pages 4.49 Kb

CAP 600 specifications

The Kathrein CAP 600 is a cutting-edge solution designed for the modern telecommunications landscape, catering primarily to the demands of mobile network operators and service providers. This compact, high-performance active antenna system is engineered to enhance connectivity in urban environments, significantly improving network efficiency and user experience.

One of the key features of the Kathrein CAP 600 is its multi-band capability. It supports various frequency bands including LTE, 5G NR, and others, making it versatile for both current and future network deployments. This allows operators to seamlessly upgrade their services without needing to overhaul their infrastructure.

The CAP 600 is equipped with advanced MIMO (Multiple Input Multiple Output) technology, which leverages multiple antennas at both transmitting and receiving ends to boost data throughput and reliability. This technology is essential for maximizing spectral efficiency, thus accommodating more users and higher data rates in dense urban areas.

In terms of design, the Kathrein CAP 600 features a compact and lightweight structure. This is crucial for installations in constrained environments where space is at a premium. The antenna's sleek aesthetics also allow it to blend into its surroundings, thereby reducing visual impact, which is often a concern in urban deployments.

The antenna incorporates intelligent software features that facilitate dynamic beamforming. This enables targeted coverage, allowing signals to be directed towards users rather than being broadcast in all directions, thus minimizing interference and optimizing network performance. Additionally, the built-in remote management capabilities allow operators to monitor and manage network performance in real-time, enhancing operational efficiency.

Regarding sustainability, the CAP 600 is designed with energy efficiency in mind. The use of advanced materials and optimized hardware contributes to lower energy consumption, making it an environmentally friendly choice for operators looking to reduce their carbon footprint.

Overall, the Kathrein CAP 600 is a sophisticated solution that meets the high demands of modern mobile networks. With its advanced features, technologies, and commitment to sustainable operations, it represents a pivotal component for any operator looking to enhance connectivity and provide exceptional service in today’s dynamic telecommunications environment.