You must use ServeRAID version 4.10 or later for your ServeRAID controller to report status and alerts properly. To download the latest ServeRAID family software, visit the following IBM web site at: http://www.ibm.com/pc/support.
For
For Netfinity Manager users, download Netfinity Manager version 5.20.6 SP1 or later.
For Netfinity Director users, download Netfinity Director, UM Server extensions version 2.12 SP1.
Symptom-to-FRU index
This index supports Netfinity EXP300 – Type 3531 expansion units.
Use this chart to find solutions to problems that have definite symptoms.
Problem indicator | FRU/Action | |
|
|
|
Amber LED on Drive CRU | 1. | Failed drive |
| Refer to “Replacing | |
|
|
|
Amber LED on ESM board | 1. | Failed ESM board |
| Refer to “Replacing an ESM board” on page 24. | |
|
|
|
Amber LED on front panel | 1. | Indicates that a Fault LED somewhere on the expansion |
|
| unit has been turned on. (Check for amber LEDs and |
|
| CRUs.) |
| Refer to “Rear controls, indicators, and connectors” on page | |
| 15 |
|
|
|
|
Amber LED on and green LED off | 1. | Turn on all power supplies |
| 2. | Power supply |
|
|
|
Amber and green LEDs on | 1. | Failed power supply |
|
|
|
All green LEDs off | 1. | Check that all expansion unit power cables are plugged |
|
| in and the power is on. If applicable, check that the |
|
| main circuit breakers for the rack are turned on. |
| 2. | Check the main circuit breaker and ac outlet. |
|
| If the external switch 1 is set to Off, the SCSI controller |
|
| must be cabled to the EXP300 and turned on. |
| 3. | Power supply |
| 4. | |
|
|
|
Amber LED flashing on Drive CRU | 1. | Drive rebuild or identity is in process. |
|
|
|
Amber LED flashing on power | 1. | Power supply |
supply |
|
|
|
|
|
Amber LED on and green dc power | 1. | Turn power switch on |
LED off on power supply | 2. | Power supply |
| ||
|
|
|
Netfinity EXP300 Type 3531 7