IBM 3531 manual ESM and power supply bays, Switch card bay, Hot-swap ESM bays

Page 21

Attention: Never remove the bridge card while the expansion unit is turned on. Refer to “Turning the expansion unit on and off” on page 3.

ESM and power supply bays

The following illustration shows the location of the environmental services monitor (ESM) bays (for the hot-swap ESM boards) and the power supply bays where the hot- swap power supplies are located.

Hot-swap ESM bays

0 1

2

7

65

Hot-swap power supply/fan bays

Hot-swap ESM bays

These are the locations of the environmental services monitor (ESM) boards. The ESM boards provide a SCSI interface to the drives and monitor the overall status of the expansion unit. The ESM boards are hot-swappable. Refer to “Replacing an ESM board” on page 24 for step-by-step instructions.

Hot-swap power supply/fan bays

Your expansion unit comes with two 500 Watt hot-swap and redundant power supplies with built-in fans. The power supplies are redundant in that a single power supply can provide adequate power and cooling for the entire expansion unit. A single power supply can support up to 14 disk drives; however, both power supplies must be installed, even if one power supply is not operational. Refer to “Working with hot-swap power” on page 21 for step-by-step instructions.

Switch card bay

Your expansion unit comes with a switch card that contains five external option switches and four internal option switches. The switch card is located on the back of the expansion unit between the two power supplies. The switch card contains switches that control how power is supplied to the expansion unit and what expansion unit services are enabled (for example, switching between a tower configuration and a rack configuration or switching between a single bus and a dual- bus configuration.) In a dual-bus configuration, each bus uses seven drives. A single- bus configuration uses all 14 drives. To access the four internal option switches, you must turn off the expansion unit; then remove the switch card. Refer to “Replacing the switch card” on page 23 for step-by-step instructions.

Attention: Never remove the switch card or change the switch card settings while the expansion unit and host server is turned on. Refer to “Turning the expansion unit on and off” on page 3.

In addition to the internal and external option switches, the switch card also has a 10- position unit ID switch for setting the expansion unit ID using values 0 through 9.

Netfinity EXP300 Type 3531 13

Image 21
Contents Ff X pypi Page Ff X pypi Page About this manual Important safety informationOnline support Contents Page Netfinity EXP300 Type FeaturesClustering support GeneralDisk drive storage Diagnostics and Test Information Problem ReferenceTurning on the expansion unit Turning off the expansion unit Operating specifications Turning off the expansion unit in an emergencyTurning on the expansion unit after an emergency System-management software support Symptom-to-FRU index Locations Getting started Preparing the expansion unit Use safe practices when liftingRemoving CRUs StatementExternal option switches Setting the interface options and ID settingsInternal option switches Option switch 1 Power-control switchUnit ID dial switch Hot-swap drive bays Netfinity EXP300 baysBridge card bay Important information for IBM ServeRAIDSwitch card bay ESM and power supply baysHot-swap power supply/fan bays Hot-swap ESM baysPower-on LED green Front controls, indicators, and devicesPower-supply controls, indicators, connectors Rear controls, indicators, and connectorsESM board user controls Working with hot-swap drives Installing hot-swap drives LED State DescriptionHard disk drives ServeRAID information Replacing hot-swap drives Removing a hot-swap power supply/fan unit Working with hot-swap powerInstalling a hot-swap power supply / fan unit Working with cards and boardsReplacing a bridge card Installing a bridge card Replacing the switch cardRemoving the switch card Removing a bridge cardReplacing an ESM board Conversion of EXP300 to a tower or from a tower Installing the EXP300 in a rack Netfinity EXP300 Type 3531 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Installing the EXP300 in a Tower Statement Installing identification labels Serial number label Scsi ID label Expansion unit ID label Installing the EXP300 in a NetBAY enclosure FrontRear Completing the installation Cabling the expansion unit Index System Netfinity EXP300 Type FRU No Parts Listing SystemOptions Power Cords IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual General safety Safety informationElectrical safety Safety inspection guide Handling electrostatic discharge-sensitive devices Grounding requirements Safety notices multi-lingual translationsDo not Statement ≥18 kg 37 lbs ≥32 kg 70.5 lbs ≥55 kg 121.2 lbs IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Perigo ImportanteCuidado Para Conectar Para DesconectarAo levantar a máquina, faça-o com segurança Instrução IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information Connexion Déconnexion Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Vorsicht WichtigAchtung Kabel anschlieβen Kabel lösenVorsicht Achtung Pericolo Attenzione Per collegare Per scollegarePericolo Attenzione Related service information IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual Related service information Peligro Apáguelo Para la conexin Para la desconexiínPeligro Precaución Problem determination tips Send us your commentsThank you for your response Trademarks IBM Page Part Number 06P8514