![](/images/new-backgrounds/1278433/278433111x1.webp)
CHAPTER 3 OPERATING THE EMULATOR
3.6User Data Bus Switching
Set the setting of the user data bus selection switch.
■Switching of the user data bus
CAUTION
Make sure that power to the product is turned off and the power plug is
Prohibition disconnected from outlets before handling switches. Doing so may result in device problems or electric shock.
If probing target pins (P00 to P07 and P10 to P17) have special specifications, such as for high- voltage ports, the user data bus probing circuit must be set to the disconnected status.
When the external bus of the evaluation MCU is not used, the disconnected status is the recommended setting for the user data bus probing circuit.
Using the user data bus selection switch on the emulator, set the user data bus probing circuit to the connected or disconnected status.
Figure 3.6-1 "Configuration of the peripheral circuit for the user data bus selection switch" shows the configuration of the peripheral circuit for the user data bus selection switch. Table 3.6-1 "Settings of user data bus selection switch" lists switch settings.
Table
Probing target pin | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
|
|
|
|
|
|
|
|
|
| |
P00 to P07 | Connected | ON | ON | ON | ON | ON | ON | ON | ON | |
(P0 SENSE setting) |
|
|
|
|
|
|
|
|
| |
Disconnected | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ||
| ||||||||||
|
|
|
|
|
|
|
|
|
| |
P10 to P17 | Connected | ON | ON | ON | ON | ON | ON | ON | ON | |
(P1 SENSE setting) |
|
|
|
|
|
|
|
|
| |
Disconnected | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF | ||
| ||||||||||
|
|
|
|
|
|
|
|
|
|
Note:
This circuit has a function equivalent to that of a
If all buses in the evaluation MCU and user system are in the
42