Axis Communications 243Q Blade Link-Local IPv4 address, NAT traversal port mapping for IPv4

Page 44

AXIS 243Q Blade - System options 44

Link-Local IPv4 address

Link-Local Address is enabled by default and assigns the network camera with an additional IP address for the UPnP protocol. The network camera can have both a Link-Local IP and a static/DHCP IP address at the same time - these will not affect each other. See UPnP™, on page 46.

HTTP

The default HTTP port number (80) can be changed to any port within the range 1024-65535. This is useful for simple port mapping.

HTTPS

The default HTTPS port number (443) can be changed to any port within the range 1024-65535. This is useful for simple port mapping.

NAT traversal (port mapping) for IPv4

Use NAT traversal when the AXIS 243Q Blade is located on an intranet (LAN) and you wish to make it available from the other (WAN) side of a NAT router. With NAT traversal properly configured, all HTTP traffic to an external HTTP port in the NAT router will be forwarded to the network camera.

FTP

The FTP server running in the AXIS 243Q Blade enables the upload of new firmware, user applications, and so on. Check this box option to enable the service.

RTSP

The RTSP protocol allows a connecting client to start an MPEG-4 stream. Check the box to enable the RTSP server and enter the RTSP port number to use. The default setting is 554, and the allowed port range is 1024-65535. Note that MPEG-4 streams will not be available if this is not enabled.

Network traffic

Connection type - The default setting is Auto-negotiate, that is, the correct speed is automatically selected. If necessary, the connection speed can be set by selecting it from the drop-down list.

Maximum bandwidth - Specify, in Mbit/s or kbit/s, the maximum bandwidth that the camera is allowed to use on the network. This is a useful function when connecting the camera to busy or heavily loaded networks. The default setting is Unlimited.

Note: When using MPEG-4 as the video format, remember that setting a maximum bandwidth value here may create problems for individual video streams if the maximum value is less than the sum of the bit rates set for the video streams.

For more information, please see the online help .

Image 44
Contents Axis 243Q Blade Video Server User’s Manual About This Document Page Contents Axis 243Q Blade Product description OverviewLED indicators Switches & connectorsAxis 243Q Blade Product description Accessing the video server Access from a browserLayout Setting the root passwordLive View Axis 243Q Blade Accessing the video server Motion Jpeg Video streamsVideo stream types How to stream MPEG-4 MPEG-4 protocols and communication methodsRTP/RTSP/HTTP or RTP/RTSP/HTTPS Other methods of accessing the video streamAxis Media Control AMC Other MPEG-4 clients Configuring the video server Accessing the Setup linkImage appearance Image settingsVideo & Image Test Text overlay settingsVideo stream Video source settings Advanced MPEG-4 settingsBit Rate control Overlay/Mask Advanced Mjpeg settingsOverlay/Mask Settings Image Formats Image Size Overlay image requirementsOverlay image limitations Live View Config Default Video FormatDefault Viewer Viewer SettingsAction Buttons User-defined LinksCheck Show custom link Output ButtonsPan Tilt Zoom Installing PTZ devicesAuthentication key PTZ configuration Preset positionsPTZ controls Control panel Using CGI links to control PTZ devicesPTZ control modes Guard tour AdvancedPTZ control queue Using PTZ on video inputs Event types Event configurationEvent servers How to set up a triggered event Triggered EventClick Add triggered... on the Event Types Enter the minimum time interval between triggersClick Add scheduled... on the Event Types How to set up a scheduled eventScheduled event Camera tampering Motion detection How to configure Motion DetectionClick Motion Detection in the Event Config menu Port status Object SizeSystem options SecurityUsers IP Address FilterHttps IeeeAuthentication process RadiusDate & time Axis 243Q Blade System options CA serversBasic TCP/IP settings IPv4 and IPv6 Address ConfigurationServices NetworkDNS configuration Host Name ConfigurationNetwork traffic Link-Local IPv4 addressNAT traversal port mapping for IPv4 Smtp email QoS Quality of serviceQoS Settings Ports & devices UPnPBonjour Maintenance SupportSupport Overview System OverviewAccess Log The Access Log may be used for various purposes AboutResetting to the factory default settings Terminal connector Pin Function DescriptionRS-485-A Non-invertingSchematic diagram I/O terminal connector Axis 243Q Blade10o 11oRS-485 COM port Upgrading the firmware TroubleshootingChecking the firmware Emergency recovery procedure Axis 243Q Blade cannot be accessed from a web browser Alarms, to a destination outside the local networkServer is inaccessible Video Image ProblemsSnapshot images Only I framesTechnical specifications NTSC/PALMaintenance Weight General performance considerations Optimizing your systemBandwidth Glossary Axis 243Q Blade GlossaryCompression See Image compression De-interlacing See InterlacingEncoder See Video encoder Fixed iris See AutoirisAn IP address consists of four groups or quads Megapixel See Pixel Axis 243Q Blade Glossary SSL/TSL An I-VOP is a complete image frame Factory default settings 49 firmware Live view configIndex Generic Http Generic TCP/IPLive View Video source Video streams 12, 14, 18 Viewer settings