Toshiba kV-9168A Time Mode button is pressed, the display, Button twice to erase, Menu screen

Page 27

Press the + or – SET

6 button and the SHIFT button to set start time to 8:30.

DISPLAY TIME MODE +

SET

 

SHIFT

TRACKING

 

 

LOCATION SELECT

PROGRAM FR1 ON --:-- --:-- SP120 FR2 ON --:-- --:-- SP120 SA1 ON --:-- --:-- SP120 SA2 ON --:-- --:-- SP120 SU1 ON --:-- --:-- SP120 SU2 ON --:-- --:-- SP120

 

 

 

 

DLY

ON

8:-- --:-- SP120

EXT

ON

 

SP120

 

 

 

MENU=[DISPLAY]

PROGRAM FR1 ON --:-- --:-- SP120 FR2 ON --:-- --:-- SP120 SA1 ON --:-- --:-- SP120 SA2 ON --:-- --:-- SP120 SU1 ON --:-- --:-- SP120 SU2 ON --:-- --:-- SP120

DLY

ON

8:30 --:-- SP120

EXT

ON

SP120

 

 

MENU=[DISPLAY]

i

The TIME MODE button is pressed, the display

INTRODUCTION

 

changes as follows.

 

 

 

SP120 120 SP168

168 SPL01 SPL02

 

 

 

SPL03 SPA2 A6 SPA12 A18 SPA24 SP24

 

 

30 SP48 48 SP72 72 SP120

 

i

The TIME MODE button is pressed, the display

 

 

changes in the reverse direction.

 

 

Press the DISPLAY

 

PREPARATION

 

button twice to erase the

9 MENU screen.

 

 

 

DISPLAY TIME MODE +

 

 

 

SET

 

 

 

SHIFT

TRACKING

 

 

 

8/28/97 THU

 

LOCATION SELECT

 

 

17:30:02SPA 2

 

 

 

 

 

10 Press the TIMER button.

 

Press the SHIFT

7 button to blink end time. Set end time to 17:00 with the SET button and the SHIFT button in the same manner as 6.

DISPLAY TIME MODE +

SET

PROGRAM FR1 ON --:-- --:-- SP120 FR2 ON --:-- --:-- SP120 SA1 ON --:-- --:-- SP120 SA2 ON --:-- --:-- SP120 SU1 ON --:-- --:-- SP120 SU2 ON --:-- --:-- SP120

DLY

ON

8:30 17:30 SP120

EXT

ON

SP120

 

 

MENU=[DISPLAY]

 

 

H

 

TIMER

REC

EP

RECORDING OPERATION

 

 

 

 

TIMER

i The power goes off and the TIMER display lights in the

VCR display.

 

 

i Recording starts at the programmed start time.

 

SHIFT

TRACKING

PROGRAM

Notes:

LOCATION SELECT

FR1 ON --:-- --:-- SP120

FR2 ON --:-- --:-- SP120

SA1 ON --:-- --:-- SP120

SA2 ON --:-- --:-- SP120

SU1 ON --:-- --:-- SP120

SU2 ON --:-- --:-- SP120

DLY

ON

8:30 17:00 SP120

EXT

ON

 

SP120

 

 

 

MENU=[DISPLAY]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i If the TIMER button is pressed at the moment between

 

start time and end time, recording starts immediately.

 

i To cancel the timer recording, press the TIMER button.

 

i The timer recording starts 10 seconds before the record

PLAYBACK OPERATION

start time.

i When the end time is set to a time earlier than the start time, the

recording is carried out up to the end time in the next day.

 

Press the SHIFT

8 button and the + SET button to set recording time mode to SPA24.

DISPLAY TIME MODE +

SET

 

SHIFT

TRACKING

 

 

LOCATION SELECT

PROGRAM FR1 ON --:----:--SP120 FR2 ON --:----:--SP120 SA1 ON --:----:--SP120 SA2 ON --:----:--SP120 SU1 ON --:----:--SP120 SU2 ON --:----:--SP120

DLY ON

8:30 17:00 SPA24

EXT ON

SP120

 

MENU=[DISPLAY]

i The time difference between start time and end time

should be more than 1 minute. If they are same, timer

recording doesn’t work.

i The accuracy of the time display depends on the condi-

tions of use and the environment. Set clock to the exact

time by daily check.

i During timer power off mode, alarm recording will not

operate at all.

During the 12 hour display, the display appears as follows.

IF A POWER FAILURE SHOULD OCCUR

iIf a power failure occurs, the PW.FAIL display appears in the VCR display. To erase this display press one of the operations buttons.

iIf the power failure is recovered within 10 days, and the battery is charged continuously for more than 48 hours in the ambient temperature, the date/time data and timer recording programs remain in the memory.

 

 

 

 

 

NOTICE

 

PROGRAM

 

 

 

 

FR1 ON -:--- -:--- SP120

 

 

FR2 ON -:--- -:--- SP120

 

 

SA1 ON -:--- -:--- SP120

 

 

 

SA2 ON -:--- -:--- SP120

 

 

 

SU1 ON -:--- -:--- SP120

 

 

 

SU2 ON -:--- -:--- SP120

 

 

 

DLY ON 8:30AM 5:00PM

SPA24

 

 

 

EXT ON

SP120

 

 

 

MENU=[DISPLAY]

 

 

 

 

 

 

 

 

 

 

 

26

Image 27
Contents Instruction Manual Please Read Important PrecautionsUnplug this product from the wall Important Safety InstructionsPower Sources Radiators, heat registers, stovesTo restore the product to its normal operation AccessoriesPower Lines When the power-supply cord or plug is damagedTable of Contents FeaturesFront Panel Instructions in BriefDisplay button Time Mode / SET + buttonsTape Remain button Cassette CompartmentRear Panel Removal Word on the Exclusive 3N-100AAS Battery PackSpecification of Battery InstallationVCR Display REW button Press to start play backFF button Connection with a Video Camera ConnectionsOutput Typical Connection with the Sequential SwitcherVideo To REC TRIGG. OUTContents of Screen Display Alarm Recall Screen Operation Setting the ClockMonitor screen ON-SCREEN FunctionsDate-Time Display VCR displayDisplay Screen This function enables to indicate and record information Alarm numberIs pressed. When an alarm is Changes to the alarm numberAlarm Memory Counter DisplaysCounter Memory Error Message Tape RemainCode Number Condition of Abnormality Setting the RECORDING/PLAYBACK Time HOW to Operate 24 Hour Virtual Real Time ModeA18 20s Fields/s Possible Continuous Virtual Real Time mode Loading and Unloading a Video Cassette Loading a cassetteUnloading a Cassette Camera and monitor TV RecordingRestart Recording Setting the Restart RecordingProgram Screen Timer RecordingSetting the Timer Program Daily Timer RecordingDuring timer power off mode, alarm recording will not Time Mode button is pressed, the displayPower goes off and the Timer display lights Should be more than 1 minute. If they are same, timerWeekly Timer Recording Press the Shift ButtonGRAM.to blink PROPress the Shift Button to blink the MO1 start time DLY Overlapping ProgramsExample FR2Event Recording Alarm RecordingOperation at Alarm Input Alarm Recall DisplayConnecting the Alarm Terminals Manual Setting the Alarm RecordingDisplay Recording time ContAuto recording Connecting the External control terminalAuto Recording Operation of Auto RecordingPress the + or SET How to release Auto RecordingHow to forbid Auto Recording Press Timer button to release the timer modeDisplay Operation after detection of tape end How to Set to Stop at End of TapeSetting contents Buzzer Screen display Counter display Operation After Tape END DetectionHow to Set to Auto Rewind at End of Tape Alarm recording does not operate during auto-rewindMenu Screen ButtonREC. to select REW → How to Set to Repeat Record at End of TapeC D a B C D Recording with the Sequential SwitcherConnection with the Sequential Switcher Timing for Camera SwitchingREC Trigger Output Selection in the Alarm Recording Tracking Adjustment Recording time mode Time mode for playbackPlayback Slow Still Play Using the Shuttle DialREW Stop Picture Search PlayPlayback in Various Modes Search Operation Time Date SearchPress the Counter Memory button twice to make Alarm SearchAlarm M to light Still picture mode Press the Play buttonInput/Output Terminal Signal level Additional remarks Signal Levels of INPUT/OUTPUT TerminalsOrder of Daily Checks Check the playback picture recorded in SPA2 modePress the or Time Mode button to go to SPA2 mode Daily and Periodic InspectionTape Usage Frequency Recording Usage frequency Time modeSteps to Take after Daily Checks Request for Periodic ChecksDew Condensation Recording Before Calling Service PersonnelInstallation Function/OperationOther matters PlaybackDew caution sheet SpecificationsConnector section Accessories70971825 Limited Warranty