TOSHIBA | ‘99/06/26 Version 1.0 |
12.2I/F connector (SCSI connector)
12.2.1Pin No. table of connector terminal
Pin | Signal | Pin | Signal |
1 | Ground | 2 | DB0 |
3 | Ground | 4 | DB1 |
5 | Ground | 6 | DB2 |
7 | Ground | 8 | DB3 |
9 | Ground | 10 | DB4 |
11 | Ground | 12 | DB5 |
13 | Ground | 14 | DB6 |
15 | Ground | 16 | DB7 |
17 | Ground | 18 | DBP |
19 | Ground | 20 | Ground |
21 | Ground | 22 | Ground |
23 | Ground | 24 | Ground |
25 | Open | 26 | TERMPWR |
27 | Ground | 28 | Ground |
29 | Ground | 30 | Ground |
31 | Ground | 32 | ATN |
33 | Ground | 34 | Ground |
35 | Ground | 36 | BSY |
37 | Ground | 38 | ACK |
39 | Ground | 40 | RST |
41 | Ground | 42 | MSG |
43 | Ground | 44 | SEL |
45 | Ground | 46 | C/D |
47 | Ground | 48 | REQ |
49 | Ground | 50 | I/O |
*Notes 1) the low level of all signals returns TRUE.
Use Hirose Electronics Co. HIF
The voltage is added on the TERMPWER signal from the internal side of a drive. The maximum power supply current from internal side of a drive is 1.1A. If the current exceeds this level, the internal current limiter operates to stop the voltage addition. After the cause of excess current is removed, the signal returns to the original status.
Page 22 | Product Specification |