Other Requirements
Air supply
ITEM |
| Pressure/Volume | ISO8573.1 standard |
|
|
|
|
Machine |
| 80 psi at 9 ft3/min 4 | Class |
As cutting gas |
| 140 psi at 35 ft3/min 5 | Class |
Dust collector - Torit |
| 9 scfm at | Class |
|
|
|
|
Dust collector - Farr |
| 12 scfm at 90 psi |
|
|
|
|
|
Laser Oscillator Gas |
| see laser | n/a |
|
|
|
|
Assist gases |
| see assist gas recommendations (p. 10 ) | n/a |
|
|
|
|
Coolant |
|
| |
Chiller coolant includes the following: |
| ||
|
| ||
Distilled water | (Koolant Kooler: 75 gallons, CKD: 100 gallons, Orion: 50 gallons) | ||
|
| ||
Additive (provided with machine) 6 | 1 gallon provided (mix 1:100 additive:water) |
Connections
Hoses to connect air supplies to machine and dust collector
Laser
Assist gas (oxygen minimum) (see page 10)
42 micron maximum particulate size
5Pressure and flow based on process requirements (material type and thickness) - contact Amada to discuss.
6ISOGUARD Corrosion inhibitor, part# 71679859. Additional quantities available from AESI, at (714)
LC3015 Theta User Installation Guide - October, 2003 | 7 |