Toshiba P600DL service manual Function of Power Panel, Power Switch and Power Indicator, On/Off

Page 12

FUNCTION OF POWER PANEL

REAR OF CABINET

O N

(1)

POWER

OFF

INSIDE OF CABINET

AC INLET

15A 125V/250V AC

AC OUTLET AC100V-240V 50/60Hz

UNSWITCHED MAX 10A

(2)

(3)

No.

Name

Function

Remark

1

Power Switch

Turn ON and OFF main power

ON/OFF

2

AC Inlet

AC 100-240V, 50/60Hz input

3P plug

3

AC Outlet

AC outlet, un-switched, max 10A

3P socket

Note 1: The AC outlet supplies un-switched power source to a second unit in a multi-projection system. Do not use it for any other purpose. Serial connection using this power outlet must be maximum four units including the 1st unit.

Note 2: The plug type of the projection unit power cable may not match the AC outlet. When power is to be supplied to another unit from this AC outlet, please purchase necessary power cable.

Note 3: About Power Supply cord

The Power Supply cord must be in accordance with the applicable standards. A three-core cord, one for ground, must be used.

The power cord must be at least 1.0mm2 and H05VV-F.

POWER SWITCH AND POWER INDICATOR

AC power source is turned-on/off with the Power Switch. When the Power Switch is turned-on, the Power Indicator lights in green color and a projection unit enters active state.

It takes about 30 seconds typically till an image is shown after Power Switch is turned-on.

In the active state, it is possible to power on/off with an external controller. When power is turned-off with an external controller, the Power Indicator lights in red color and a projection unit enters standby state.

Interval from turn-off to turn-on shall be more than 30 seconds. If the interval is not enough, the lamp may not strike. If the user continues to do this, it may shorten the life of the lamp.

The power indicator indicates also failure information of the projection unit.

The later page at appendix list shows the lamp status.

11

Image 12
Contents P600DL Safety Precaution Contents Safety Precautions for User For use of the equipment For servicing, maintenance and inspection Safety Precautions for User Precautions for USE and Maintenance Request to UserGeneral Descriptions Features Dimensions Function of I/O Panel BNCFunction of Power Panel Power Switch and Power IndicatorON/OFF Specifications Acceptable Signal Type Acceptable RGB Input Signal Timing Horizontal Timing Vertical TimingUnit-4Unit-3 Connection AT a Multi Projection SystemDisassembly HOW to Replace the LampDiassembly Power Supply Module Ballast Module Control Module .LOCATION of KEY Components and Function ModuleExploded View of the Projection Block 96pin connector .EXPLODED View of the Screen Block and Cabinet .WIRING Adjustment .ENGINE Mount Adjustment Adjustment Adjustment Adjustment Colour , Tint Multiple Screen Wall system example Electronic Circuit Explanation Electric Circuit Explanation Power FAN Lamp Power onStanby FAN StopAppendix-2 Cont VN2 ID.CLR DMD Driver Board Debug Page Debugging Flow Diagram DMD Driver BoardBad image- Horizontal bands or lines Image shifted to left Parts List Location No Description 94800807 Ballast Module Assy 100W