Epson LVP-X200A user manual Replacement of a light source lamp

Page 40

Replacement of a light source lamp

The light source lamp is designed to project the image on the LCD panel. When the light source lamp no longer functions, replace it with a new one to ensure optimum performance.

Caution:

Do not remove the light source lamp from inside of

 

this equipment immediately after using the projec-

 

tor, you may get burned because of the high tem-

 

perature of the light source lamp.

When you replace the light source lamp, press the

3.Set Lamp exchanging metal into the projector.

1)Insert metal fittings for lamp replacement in the following positions: on the front face of the lamp (2 positions), between the lamp, and on the bottom edges (4 positions).

2)Align screw holes (c) with node (d).

3)Fasten the piece into place using the two screws included (b, b’).

(d)

ENGLISH

power button to power off, then wait for 120 sec-

onds in stand-by mode to cool down the lamp and

LCD panels. Turn off the main switch, unplug the

power code from the outlet and wait one hour so

that the lamp is cool to the touch.

(c)

(e)

(b)

(b')

Lamp exchange metal

• Do not remove the light source lamp except for re-

placement. Careless treatment can cause injury or

fire.

• Do not touch the lamp directly. It may be broken

and may cause you to injure or burn yourself.

• Be sure not to drop the lamp lid screw into the pro-

jector. Also be sure also not to insert metal or any

flammable objects, it may cause fire or an electric

shock. If any objects are inserted, please unplug and

contact your dealer.

• Install the lamp securely, failure to do so it may

cause a fire.

1. Loosen the screw of

Loosen here

the lamp lid on the

 

top cover using a

 

screwdriver (+) , and

 

remove the lid.

 

Remove the lamp cover in the direc-

tion of the arrow as indicated.

Important:

Be careful not to damage the electric wire connected to this equipment.

 

Hooks

Lamp

(x 6)

4.Loosen the lamp fixing screw (e) using a screwdriver (+), and remove it.

5.Hold onto the projector

by the handle as you pull

Handle

out the lamp.

 

For the lamp you have

 

removed, do not spill liq-

 

uid on it, place it near

 

flammable objects or

 

where children can touch

 

it. Otherwise, it will cause in-

 

jury or fire.

 

6.Insert the new lamp securely into the projector body in the right direction.

7.Tight up the screws (e) which

have been removed in 4 using a screwdriver (+).

2. Loosen a screw (a) of fix-

(a)

Fixing

ing metal using a screw-

 

metal

driver (+), and remove

 

 

 

them.

 

 

Do not lose the fixing

 

(e)

metal and screws.

 

 

8.Loosen the two screws (f), (f') of lamp exchanging metal using a screwdriver, and re- move them with the metal.

9.Remove the holes from the lamp replacement metal fittings (c) from the node

(d).

(f)(f')

(e)

10. Insert the fixed metal pieces

(a)

from step 2 into the screw

 

holes (f) and (f ’), and use one

 

screw (a) to hold the piece in

 

place.

 

40

Image 40
Contents X200 English Contents Important safeguards Never remove the cabinet Do not modify this equipmentIf you break or drop the cabinet Do not face a lens to the sunOverview of the projector FINE, º, ª, FOCUS/ZOOM and Auto Position buttonsMain power Power jackPC card eject PC card insert slotOverview of the remote control RGB, VIDEO, CardBattery installation Operation areaPreparing the projector for operation Orientation of the projectorFront projection Front projection, ceiling mountGetting ready for projection Adjusting the angle of projectionGround terminal Basic connections Projector + AV equipmentCables and adapters Projector + DVD playerProjector + IBM PC or IBM PC compatibles Desktop computerPower Book When outputting to both a PC monitor and the projectorBasic connections continue Projector + MacintoshDesktop computer display connector Projector + NEC PC-98 seriesTo operate projector power on Lamp PowerLeft side ButtonTurning off the projector Volume from the speakerAuto Position button Menu operation Basic operationPicture BrightnessSignal PictureInstallation PinP/EXPANDPC Card Auto Play AudioOption VerPicture adjustment Adjustment from personal computerAdjusting the images form personal Computers in Menu displayCGA70 Gamma Correction menu MasterAdvanced feature for presentation Cursor operationStill Fast SlowSetting the Expand mode Using the Expand modeIndication Mode 4 actual size display Super impose Picture in PictureUsing the PC-CARD Setting up the PC-CARDRelease the PC-CARD Play backPC-CARD Continue Card Auto PlayAdvanced feature with PC Installation of softwarePCV PC Card Viewer EnvironmentCommand reference For Windows Starting up PCV For WindowsRecording the image For Windows Editing the presentation For Windows Command reference Starting up PCV For MacintoshRecording the image For Macintosh JpegPCV Editing the presentation For MacintoshSequencing Exchange images Pcgc Personal Computer Graphic Control ConnectionStarting up Pcgc SpacePointer Projector + NEC PC 98 seriesSetting of SpacePointer Operation of PC by remote controlFor Windows Uninstallation of software Replacement of a light source lamp How to reset the operation time meter Life of the lampMaintenance Cleaning the air-filterCleaning the projector and the ventilation slots Cleaning the lensTroubleshooting Problems Cause Possible SolutionsIndicators Indicator Shows Condition Possible SolutionsIndicator TempSpecifications Replacement parts listAccessories LVP-X200A