3M X15 manual Maintenance, Lamp

Page 41

Maintenance

Maintenance

Lamp

WARNING

HIGH VOLTAGE

 

HIGH TEMPERATURE

HIGH PRESSURE

 

►The projector uses a high-pressure mercury glass lamp. The lamp can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, when the bulb bursts, it is possible for shards of glass to fly into the lamp housing, and for gas containing mercury to escape from the projector’s vent holes.

About disposal of a lamp • This product contains a mercury lamp; do not put in trash. Dispose of in accord with environmental laws.

For lamp recycling, go to www.lamprecycle.org. (in the US)

For product disposal, contact your local government agency or www.eiae.org (in the US) or www.epsc.ca (in Canada).

For more information, call your dealer.

• If the lamp should break (it will make a loud bang when it does), unplug the power cord from the outlet, and make sure to request a replacement lamp from your local dealer. Note that shards of glass could damage the projector’s internals, or cause injury during handling, so please do not try to clean the projector or replace the lamp yourself.

Disconnect • If the lamp should break (it will make a loud bang when it does),

the plug

ventilate the room well, and make sure not to breathe the gas that

from the

comes out of the projector vents, or get it in your eyes or mouth.

power

• Before replacing the lamp, turn the projector off and unplug the power

outlet

cord, then wait at least 45 minutes for the lamp to cool sufficiently.

 

Handling the lamp while hot can cause burns, as well as damaging the

 

lamp.

Never unscrew except the appointed (marked by an arrow) screws.

Do not open the lamp door while the projector is suspended from above. This is dangerous, since if the lamp’s bulb has broken, the shards will fall out when the cover is opened. In addition, working in high places is dangerous, so ask your local dealer to have the lamp replaced even if the bulb is not broken.

Do not use the projector with the lamp door removed. At the lamp replacing, make sure that the screws are screwed in firmly. Loose screws could result in damage or injury.

Use only the lamp of the specified type.

If the lamp breaks soon after the first time it is used, it is possible that there are electrical problems elsewhere besides the lamp. If this happens, contact your local dealer or a service representative.

Handle with care: jolting or scratching could cause the lamp bulb to burst during use.

If the indicators or a message prompts you to replace the lamp (see the section "Related Messages" and "Regarding the indicator Lamps"), replace the lamp as soon as possible. Using the lamp for long periods of time, or past the replacement date, could cause it to burst. Do not use old (used) lamps; this is a cause of breakage.

41

Image 41
Contents Trademark acknowledgment About this manualThank you for purchasing this projector Contents About contents of package Projector featuresProjector Part namesMagnify Remote controlControls Fastening the lens cover PreparationsPutting batteries Using the remote control About the filter cover for bottom-up use Setting up Arrangement Adjusting the projectors elevator About Plug-and-Play capability Connecting your devicesExamples of connection with a VCR/DVD player Examples of connection with a computerConnecting power supply STANDBY/ON Power on/offTurning on the power Turning off the power Selecting an input signal Adjusting the volumeOperating Temporarily muting the soundAdjusting the zoom magnifying power Searching an input signalAdjusting the focus  At a video signal /no signal 43 Adjusting the position Using the automatic adjustment feature At a RGB signal Correcting the keystone distortionsTemporarily blanking the screen Using the partial magnify featureFreezing the screen Easy Menu Multifunctional settingsUsing the menu function Enter MenuTo reset Zoom AspectKeystone ModeEasy Menu #3 Custom  #3 Default  #2 Custom #1 Default  #1 Custom  #2 DefaultPicture menu GammaHigh  Middle Picture menuCustom  LOW Color TempProgressive TV  Film  Turn OFFLOAD1  LOAD2  LOAD3  LOAD4 SAVE4 SAVE3  SAVE2  SAVE1Image menu PhaseOver Scan PositionAuto Adjust  At a video signalImage menu SizeColor Space Input menuAuto  Ntsc  PAL  Secam Video FormatTurn on  Turn OFF Input menuFrame Lock InformationVolume Setup menuNormal  Whisper Normal  Hinvert  Vinvert  H&VINVERTMenu Position Screen menuOSD Bright BlankMyScreen Screen menuStart UP Message MyScreen LockNo Input is Detected Sync is OUT of RangeAuto Search Option menuRGB  S-VIDEO  Video Auto OFFLamp Time Reset  CancelOption menu Factory Reset ServiceFAN Speed GhostLamp MaintenanceMaintenance Case of replacement by yourselfAir filter Air filter Page Related messages Related messages Internal portion temperature is risingRegarding the indicator lamps Regarding the indicator lamps Power switch is not set to the on position Electrical power cord is not pluggedThese has not been properly fixed Phenomenon Cases not involving a machine defect ReferencePhenomena that may easily be mistaken for machine defects RGB input SpecificationCommunication port Video inputSpecifications Not included with Basic Packet Part Number Accessories Part NumberHow to Order DN00822-S15OGENG