HCD-PX333
SELF-DIAGNOSIS FUNCTION
The
Self-diagnosis display
This system has a
C11/Protected
The MD is protected against erasure.
t Remove the MD and slide the tab to close the slot.
C12/Cannot Copy
You tried to record a CD or MD with a format that the system does not support, such as a
t Remove the disc and turn off the system once, then turn it on again.
C13/REC Error
Recording could not be performed properly. t Move the system to a stable place, and start
recording over from the beginning.
The MD is dirty or scratched, or the MD does not meet the standards.
t Replace the MD and start recording over from the beginning.
C13/Read Error
The MD deck cannot read the disc information properly.
t Remove the MD once, then insert it again.
C14/Toc Error
The MD deck cannot read the disc information properly.
t Replace the MD.
t Erase all the recorded contents of the MD using the All Erase function.
C41/Cannot Copy
The sound source is a copy of a commercially available music software, or you tried to record a
t The Serial Copy Management System prevents making a digital copy (see page 44). You cannot record a
C71/Check
This appears momentarily because of the signal of the digital broadcast during recording.
t There is no affect on the recorded contents. No component is connected to the DIGITAL OPTICAL IN jack, or a digital component is not connected properly.
t Connect a digital component to the DIGITAL OPTICAL IN jack properly using a digital connecting cable.
The connected digital component is not turned on. t See the operating instructions supplied with the
connected component and confirm whether the component is turned on.
The digital connecting cable connected to the DIGITAL OPTICAL IN jack is pulled out, or the connected digital component is turned off during digital recording.
t Connect the cable, or turn on the digital component.
E0001/MEMORY NG
There is an error in the internal data that the system needs in order to operate.
t Consult your nearest Sony dealer.
E0101/LASER NG
There is a problem with the optical pickup.
t The optical pickup may have failed. Consult your nearest Sony dealer.
MD SECTION
PROCEDURE FOR USING THE
Note 1:About “R”
As this unit has only a few buttons, some operations require the use of remote commander
Example: MENU/NO “R” ...Press the [MENU/NO] button of the remote commander.
Note 2:Incorrect operations may be performed if the MD test mode is not entered properly.
In this case, press the ?/1 button to turn the power off, and retry to enter the MD test mode.
Note 3:Perform the
Procedure:
1.Press the ?/1 button to turn the power on.
2.Press the [FUNCTION] button to set the MD function.
3.Press three buttons of M>TUNING+ , [REC MODE], and .m (MD) simultaneously to enter the MD test mode and display “[Check]”.
4.Press the . “R” or > “R” button to display “[Service]”.
5.Press the ENTER/YES “R” button to display “AUTO CHECK”, and press the > “R” button to display “Err Display”.
6.Press the ENTER/YES “R” button to enter the error history mode and display “op rec tm”.
7.Select the contents to be displayed or executed using the . “R” or > “R” button.
8.Press the [CD SYNC NORMAL] button to light up “IT” indicator, then press the [REC MODE] button will display or execute the contents selected.
9.Press the [REC MODE] button another time returns to step 7.
10.Press the MENU/NO “R” button displays “Err Display” and release the error history mode.
11.To release the MD test mode, press the [REPEAT STEREO/MONO] button to display “Initialize” and release the MD test mode.
2