EN 30 |
| 5. |
| DVD963SA | Diagnostic Software, Trouble Shooting and Test Instructions |
5.6.3Trade Mode
When the player is in Trade Mode, the player cannot be controlled by means of the front key buttons, but only by means of the remote control.
TO ACTIVATE TRADE MODE
POWER ON
DURING STOP MODE AND W/O DISC. PRESS REMOTE KEYS COMBINATION
<PLAY> <259> <PLAY>
PLAYER IS IN TRADE MODE WHEN
PRESSING FRONT KEYS,
THE PLAYER DOESN'T RESPOND
TO DEACTIVATE TRADE MODE
POWER ON
DURING STOP MODE AND W/O DISC. PRESS REMOTE KEYS COMBINATION
<PLAY> <259> <PLAY>
PLAYER IS IN NORMAL MODE WHEN
PRESSING FRONT KEYS,
THE PLAYER WILL RESPOND
CL16532162_052.eps 0850102
Figure
Note: To activate and deactivate the Trade Mode with the disc in the player, the procedure is similar to above, except that the remote control keys combination is pressed at the instant when the local display is flashing “READING”
5.7Menu and Command Mode Interface
5.7.1Layout of Results Diagnostic Nuclei
Results returned from a Diagnostic Nucleus will be displayed in the following layout:
<number >< string > [ok ER]
<number >: is a
<string >: is a text string containing information about the result of the Diagnostic Nucleus.
<number > and < string > are defined in [SSD_DN] in the output sections of each Nucleus.
Examples:
1.0001Unknown command ER @
2.3100OK @
3.0901Data line X is not connected to the DRAM ER@
5.7.2Command Mode Interface
Set-up Physical Interface Components Hardware required:
• Service PC
• one free COM port on the Service PC
• special cable to connect DVD player to Service PC
The service PC must have a terminal emulation program (e.g. OS2 WarpTerminal or Procomm) installed and must have a free COM port (e.g. COM1). Activate the terminal emulation program and check that the port settings for the free COM port are: 19200 bps, 8 data bits, no parity, 1 stop bit and no flow control. The free COM port must be connected via a special cable to the RS232 port of the DVD player. This special cable will also connect the test pin, which is available on the connector, to ground (i.e. activate test pin).
Code number of PC interface cable: 3122 785 90017
Activation
Switch the player on and the following text will appear on the screen of the terminal (program):
DVDv4 Diagnostic Software version 5.03
(M)enu, (C)ommand or (S)2B interface ? [M]:@ C <enter>
SDRAM Interconnection test passed
Basic SDRAM test passed
Slave Processor: SLAVE2
DD:> | CL 26532105_058.eps |
| 020902 |
Figure
The first line indicates that the Diagnostic software has been activated and contains the version number. The second line lets the user choose the interface format. Enter ‘C’ to select Command Mode and the next three lines are the successful result of the two subsequent basic tests (nuclei 2, ,4 and the detection of the display type used by the panel respectively). If not all these messages appear on the terminal screen, then the related nucleus found an error. The last line is the prompt ("DD>"). The diagnostic software is now ready to receive commands.
Command Overview of Nuclei
The following table gives an overview of all available nuclei. The first column contains an identification number, the second contains the name of a nucleus and the last column indicate the description of the nucleus.
Note: User confirmation is necessary during front panel tests
Table 5-1 Basic diagnostic nuclei
Ref. # | Reference Name | Remark |
1 | BasicSpAcc | Serial port Access test/ |
|
| initialization |
|
|
|
2a | BasicInterconDram | Data and address bus |
|
| Interconnection (only for |
|
| development) |
|
|
|
2b | BasicInterconSdram | Data and address bus |
|
| interconnection |
|
|
|
3 | BasicDramWrR | DRAM Write Read (only for |
|
| development) |
|
|
|
4 | BasicSdramWrR | SDRAM Write Read |
|
|
|