Error Log
The stored error log can be displayed by performing the operation on page 21 “Checking Error Log”.
The error content is displayed by error code.
Display
a | b | c | d | e |
00 : Feb07 14 : 06 0001 -system boot
a:Error log No.
b:Error occurrence date
c:Error occurrence time
d:Error code
e:Error content
*For the error content with plenty of characters, press the ; / : buttons to scroll the display.
*The date and hour of this unit is adjusted to Green- wich Mean Time (GMT).
Error code
Error code:Error content | Cause of error | Troubleshooting |
|
|
|
0001: | Restart of this unit has been performed. |
|
system boot |
|
|
|
|
|
0020: | The communication error caused by control |
communication error | device communication has occurred. |
|
|
0021: | The value of command and parameter created |
command parameter error | by control device communication is abnormal. |
|
|
Confirm the connection to external device.
Confirm the setting of external de- vice.
0022: | This unit has received action command |
command busy | when it is busy. |
0040: | The synchronized signal cannot be de- |
sync input error | tected. |
|
|
0041: |
|
sync input error recover |
|
Confirm the connection to external synchronized signal generator and the synchronized signal itself.
0050: | The detection of the synchronized signal |
sync no input timeout error | has timed out when this unit restarts. |
0080: | The video input signal is abnormal. |
enc hardware video input error |
|
|
|
0081: |
|
enc hardware video input error recover |
|
Confirm the connection between
Confirm the signal input into HD- SDI IN terminal
0084: | The audio input signal is abnormal. |
enc hardware audio input error |
|
|
|
0085: |
|
enc hardware audio input error recover |
|
Confirm the connection between AES/EBU IN terminal and con- nected device.
Confirm the signal input into AES/ EBU IN terminal.
0088: | Resync process has occured when syn- |
enc hardware resync | chronizing to video input signal. |
Confirm the connection between HD- SDI IN terminal and connected device(Frequent reconnection of the connector may cause the error).
Confirm the signal input into