Stanley Black & Decker EP30250 Operation, Check that all parts were received, Connect

Page 10

EP30250 OPERATION

CAUTION

The S300 requires a welding machine capable to deliver 250-300 Amp, open circuit voltage of max. 80V.

(Not supplied by Stanley)

1. Check that all parts were received.

EP300 Unit Delivered with:

Gun S15, incl 2,7 m SAFE 91015 Ground device 2,7 m SAFE 8089 1 - Power cord

2 - Power cable 3 m

2. Connect

Connect power cords to mains and power cables to an welding machine.

(Welding machine not supplied by Stanley). Make sure positive and negative is correct.

Set welding current on welding machine to 250 Amp.

(Max 280 Amp)

Open circuit voltage of max. 80V.

Connect brazing gun, power cable and control cable, to units gun outlets. Connect ground magnet to ground outlet.

10 ► EP30200 / EP30250 User Manual

Image 10
Contents EP30 Declaration of Conformity Weisbeck, AndyTable of Contents Safety Symbols Local Safety RegulationsSafety Precautions Initial Setup and Battery Charging EP30200 OperationPlacing the Grounding Cable Select Pins and RingsPrepare the Rail Surface Changing PIN and Ring HolderLoading PIN and Ring Adjusting Brazing PIN Distance to Braze SurfaceSET Control for PIN Size EP30 does not have a power switch Check that all parts were received EP30250 OperationConnect Brazing instruction Accessories EP300 BrazingEP30250 Maintenance PIN HoldersEP30250 TroubleshootingEP30200 Equipment Maintenance & Care Specifications AccessoriesPIN & Ring Holders Brazing Pins & Ceramic Rings Standard Brazing PinsCeramic Rings Cable Lugs for Pin Brazing to railConnectors Bonding Cable with Lugs for Pin BrazingGrinder Abrasives Fuses, Chargers, & BatteriesCables GrinderPlugs GunsTools EP30 Parts Illustration Internal Electronic Control BOX EP30 Parts List