Panasonic EP30006 Press the button to start the program, Setting the Time and Intensity

Page 24

3 Set the time and intensity for the neck, shoulder, back, and lower back,

respectively ( ).

• The level shifts sequentially whenever the button is pressed.

Display

How to shift the level

 

• Press the

button to shift the levels for “NECK,” “SHOULDER,” “MIDDLE,” and “LOWER” by one up/down at the same

time.

 

3 bars represents more time than one bar.

If all areas are 3 bars, then both time will be equally long and the massage will be strong in all areas.

If all areas are just one bar, then massage length will be the same, and intensity will be lighter.

4 Press the button to start the program.

The massage will start after the body scanning.

To change the time and intensity in the middle of a massage

Set the condition again with Steps 3 and 4 .

Press the button within approximately 30 seconds after resetting in Step 3 , otherwise the reset will be cancelled automatically.

Setting the Time and Intensity

In the Self-Program, the actions and time for the respective body parts will be set according to the settings picked by the user. Fewer bars means both less time and less strength. If you don’t want a massage at all in an area, set the bars to “0”.

Massage Sequence

The massage starts in the area with the highest numbers of bars selected, and moves successively from highest to lowest.

If the levels of fatigue are the same, the massage will follow the sequence of “NECK,” “SHOULDER,” “MIDDLE,” and then “LOWER.”

Massage actions for the respective level of fatigue

Stronger massage mainly Shiatsu

Massage at an intermediate level, mainly

Kneading

Softer massage mainly Swedish

No massage for this part

During a massage

To change off/on for “LEG/FOOT,” “SEAT,” “HAND/ARM,” or “SHOULDER” and adjust its intensity, see page 30.

If you want to turn the stretch massage off/on, see page 34.

If you want to adjust the legrest, see page 35 and 36.

If you want to adjust the intensity and position of the massage on the upper body using the massage heads, see page 27 and 28.

If you want to adjust the reclining angle, see page 35.

If you want to use the “ULTRA KNEAD” function or “REPEAT” function, or change the massage style, see page 27.

If you want to finish a massage, see page 42 and 43.

23

Image 24
Contents Operating Instructions Instrucciones de Uso Important Safety Instructions Safety Precautions Operating Precautions Grounding Instructions Part names and functions Main unitBack Control Panel Voice Guidance Volume Display Self-Program Setting DisplayTime Remaining Display During massage Ultra Knead/Repeat DisplaySetting up the massage lounger Where to use the unitRemoving everything from the box and installing the unit To put the unit down on the floorAccessories Width Approx 68 cm Height Approx 66 cm Length Approx 160 cmAssembly Connecting the air plugsAttachingarmrests Attaching the control panel stand covers When removing the control panel stand cover ConfigurationRaising the backrest to the upright position Gap Flat-tip ScrewdriverPlacing the control panel into the control panel stand Inserting the shoulder plate Attaching the pillowShoulder plate Pocket Attach the pillow to the velcro fastenersCheck the power cord and the power plug Switching on the power supplyBefore sitting down Check the unitWhen the massage heads are not in the retracted position Press the button to turn on the power Pre-Program and Quick Massage Characteristics Upper BodyProgram Massages Press one of the flashing buttons To select ProgramBody scanning will commence when the program is selected When the massage starts During a massageOverview of the Pre-Program and Quick Massage Upper Body Creating Self-Programs Open the right cover and press the buttonSelf-Program Self-ProgramSetting the Time and Intensity Press the button to start the programTo change the time and intensity in the middle of a massage Massage SequenceManual Selection Massages Manual OperationManual Operation Select the location you want to massage Select the massage actionPress Button to start the action Body scanning for Manual OperationFor additional operations Ultra Knead Shiatsu SwedishAdjustments During a Massage Adjusting the speedChanging the program Changing the massage styleAdjusting the intensity Adjusting the positionWidth Adjustment Limits Adjustment of range of intensityDetails about the massage style Range that can be massaged on the upper bodyAdjusting the intensity Open the left coverTo execute the air massage only Adjusting the Legrest length Adjust the legrest so that your feet fit snuglyFor the foot reflexology plate How to use the hand/arm massage Arm MassageInsert the hand all the way inside Center of the armrest Adjustments for the Shoulder Massage Adjustments for the seat/thigh massageOuter Shoulder Massage Using the stretch massage Operations of the leg stretchOperations of the arm stretch To execute the stretch massage onlyOttoman and Backrest height adjustment Legrest slide lever Adjusting the voice guidance volume Press Button to adjust the volumePress the button to shift the volume level by one up/down Adjusting the control panel stand and pillow Adjusting the control panel standAdjusting the pillow for correct height during a massage Saving the user program settings When the selected button starts flashing quicklyPress the button used to save your settings Advanced user memory functionSettings that can be saved For Pre-Program, Quick Massage, and Self-ProgramFor Manual Operation Erasing saved data Press the button to turn on the power When the massage is complete After completing the massageEmergency Stop Press the button Disconnecting the power Keep the lock switch key out of reach of childrenCleaning and Maintenance Areas covered with synthetic leatherWipe these areas with a soft, dry cloth Moving the Unit Lifting the UnitDo not move the unit while someone is seated in it Using the wheels to move the unit Problem Cause and Remedy Motor Noises Massage heads stop during operationMassage heads do not come up to the shoulder or NeckProblem Cause and Remedy Unit will not operate at all Sometimes the power won’t turn on when Is pressedAgain when a massage has finished Power cord or power plug is abnormally hotPanasonic Consumer Electronics Company