Panasonic EP30006 After completing the massage, Emergency Stop Press the button

Page 43

After completing the massage

The massage will be completed in approximately 15 minutes. For a quick massage, 5 minutes.

Since the foot section pivots, the legrest will return to a down and retracted position so that you can safely sit up. To return the

back of the chair to the original position, press the button twice. The chair does not automatically come up since you may be resting comfortably.

Interrupting the massage

1 Return the legrest to the original position and then press the

button.

• The massage heads move to the retracted position.

 

• The legrest lowers and the backrest rises automatically. The backrest will move after the massage heads retract.

Pull the legrest

slide lever back.

Raise the legs slightly and the legrest returns.

When the massage is complete

The buttons will flash and the unit ready to save any settings that changed during the massage.

Not saving the settings

It is not necessary to operate. The operation will complete after approx. 15 seconds.

Saving the settings

See pages 39 to 41 “Advanced user memory function.”

Emergency Stop

1 Press the button.

• All operations will stop immediately.

The user program will not be saved in this case.

• Get off the unit carefully to prevent the unit tipping over.

42

Image 43
Contents Operating Instructions Instrucciones de Uso Important Safety Instructions Safety Precautions Operating Precautions Grounding Instructions Main unit Part names and functionsBack Control Panel Ultra Knead/Repeat Display Voice Guidance Volume DisplaySelf-Program Setting Display Time Remaining Display During massageTo put the unit down on the floor Setting up the massage loungerWhere to use the unit Removing everything from the box and installing the unitWidth Approx 68 cm Height Approx 66 cm Length Approx 160 cm AccessoriesConnecting the air plugs AssemblyAttachingarmrests Attaching the control panel stand covers Gap Flat-tip Screwdriver When removing the control panel stand coverConfiguration Raising the backrest to the upright positionPlacing the control panel into the control panel stand Attach the pillow to the velcro fasteners Inserting the shoulder plateAttaching the pillow Shoulder plate PocketCheck the unit Check the power cord and the power plugSwitching on the power supply Before sitting downWhen the massage heads are not in the retracted position Press one of the flashing buttons To select Program Press the button to turn on the powerPre-Program and Quick Massage Characteristics Upper Body Program MassagesBody scanning will commence when the program is selected During a massage When the massage startsOverview of the Pre-Program and Quick Massage Upper Body Self-Program Creating Self-ProgramsOpen the right cover and press the button Self-ProgramMassage Sequence Setting the Time and IntensityPress the button to start the program To change the time and intensity in the middle of a massageManual Operation Manual Selection MassagesManual Operation Body scanning for Manual Operation Select the location you want to massageSelect the massage action Press Button to start the actionUltra Knead Shiatsu Swedish For additional operationsChanging the massage style Adjustments During a MassageAdjusting the speed Changing the programAdjusting the position Adjusting the intensityRange that can be massaged on the upper body Width Adjustment LimitsAdjustment of range of intensity Details about the massage styleOpen the left cover Adjusting the intensityTo execute the air massage only Adjust the legrest so that your feet fit snugly Adjusting the Legrest lengthFor the foot reflexology plate Arm Massage How to use the hand/arm massageInsert the hand all the way inside Center of the armrest Adjustments for the seat/thigh massage Adjustments for the Shoulder MassageOuter Shoulder Massage To execute the stretch massage only Using the stretch massageOperations of the leg stretch Operations of the arm stretchOttoman and Backrest height adjustment Legrest slide lever Press Button to adjust the volume Adjusting the voice guidance volumePress the button to shift the volume level by one up/down Adjusting the control panel stand Adjusting the control panel stand and pillowAdjusting the pillow for correct height during a massage Advanced user memory function Saving the user program settings When the selected button starts flashing quickly Press the button used to save your settingsFor Pre-Program, Quick Massage, and Self-Program Settings that can be savedFor Manual Operation Erasing saved data Press the button to turn on the power After completing the massage When the massage is completeEmergency Stop Press the button Keep the lock switch key out of reach of children Disconnecting the powerAreas covered with synthetic leather Cleaning and MaintenanceWipe these areas with a soft, dry cloth Lifting the Unit Moving the UnitDo not move the unit while someone is seated in it Using the wheels to move the unit Neck Problem Cause and Remedy Motor NoisesMassage heads stop during operation Massage heads do not come up to the shoulder orPower cord or power plug is abnormally hot Problem Cause and Remedy Unit will not operate at allSometimes the power won’t turn on when Is pressed Again when a massage has finishedPanasonic Consumer Electronics Company