16.If you plan to operate the NCM module under local control, perform the following steps; otherwise, go to step 17 for remote control. Local control is recommended for NMS application mode.

a.Set to local control by placing DIP switch SW10-3 in the UP position.

b.Turn service on by placing DIP switch SW10-4 in the UP position.

c.Slide the module into the selected module slot until it is firmly seated and the module front panel is flush with the top and bottom of the shelf.

d.Go to step 18.

17.If you plan to operate the NCM module under remote control, perform the following steps:

a.Set to local control by placing DIP switch SW10-3 in the UP position.

b.Turn service off by placing DIP switch SW10-4 in the DOWN position.

c.Slide the module into the selected module slot until it is firmly seated and the module front panel is flush with the top and bottom of the shelf.

d.Wait 15 seconds for the NCM module’s parameter settings to be loaded into the shelf Common Module.

e.Pull the module out of the shelf and set to remote control by placing DIP switch SW10- 3 in the DOWN position.

Do not move SW10-4.

f.Slide the module back into the shelf.

g.Verify the module configuration through remote control by issuing a “CONFIG?” query. See the Remote Control Interface section of this Instruction Data Sheet for an explanation of the “CONFIG?” response.

h.Turn service on through remote control by issuing a “SRVC=ON” command.

The operating parameters of the NCM module can now be changed by remote control. See the Remote Control Interface section of this Instruction Data Sheet for more information.

i. Go to step 18.

18.On the Module Record Card located to the right of the shelf, record the channel bank type, time slot, and any other pertinent information.

19.The NCM module is now installed. If your multiplexer is set up for remote access and control, you can now change the operating parameters of the module by using simple commands. For more information on remote access and control, consult your multiplexer operation manual.

RFL NCM

 

RFL Electronics Inc.

November 6, 2007

19

(973) 334-3100

Image 19
Contents Description RFL NCMRFL NCM NMS Mode Ascii Character Addressing Format SpecificationsInstallation RFL NCM MA-402I Module adapter, connector pinouts MA-485 Module adapter, jumper functions and TB1 pinouts MA-490 RFL NCM Front Panel View of RFL NCM, Network Communications Module Typical network example with all nodes having an NCM module At node 3, SW7 is set as follows Controls and indicators, RFL NCM Module Name/Description Function RFL NCM PRA Actel probe a NMS NMSDown SW2-3 SW2-4 Do not move SW10-4 Functional Description Block diagram, RFL NCM moduleSystem Overview Logic Array Actel Design NCM Backplane and Power ConnectionsTX Input Ports RX Output PortsApplication Modes and Interfaces SCB ModuleUart Receive Section T1 Transmit Module Uart Transmit SectionBaud and Clock Generator T1 Receive ModuleRogue Control LOOP-BACKSTest Equipment Required TestingPower indicator should be lit Service LED should be illuminated greenDS1 Power indicator should be lit DS1-B Equip OUT RXA LED should be illuminated red CH1 DS1-B Equip OUT CH2 NCM General Configurations and Status window for Node Remote Control Using NMSMode Module EnableE1 Signaling Time SlotTypical 3-node network using MA-485s 1 RS-485 port Rogue Detection Bus a & Bus BLocal CM Address NCM Address Configurations and Status window for NodeCM Address Passing Data Bits Baud RateParity Port 2 Enable TroubleshootingLoopback Channel Card 3, Type 117 Under Remote Control Svce = on Remote Control Using SCL CommandsCodes Srvc = on Srvc = OFF Multiplexer Addresscard ADDRESSSETP1 = B00000011Timeslot Selection BUS a SettingBUS B Setting CAS SettingWord Length Settings Port Loopback SettingsBaud Settings Parity SettingsSettings CM Address Pass SettingsNMS Mode only Application ModeCodes Port 2 Availability MUX Type & Configuration StatusType ID Port 1 AvailabilityPort 2 Application Status Application Configuration StatusCM Addressing Support Port 1 Application StatusCurrent Actel REV RXA Remote CM AddressPort 2 INPUT/OUTPUT Status Port 1 INPUT/OUTPUT StatusTXB/RXA Status for T1/E1 TXA/RXB Status for T1/E1Powerville Road