RF-Link Technology RFL NCM Multiplexer Addresscard ADDRESSSETP1 = B00000011, Srvc = on Srvc = OFF

Page 42

NOTE

When using binary numbers with a SET command, they must be preceded by the letter “B” as shown in the following example:

<MULTIPLEXER ADDRESS>:<CARD ADDRESS>:SET:P1 = B00000011;

Besides using the P code, it is also possible to turn module service on or off by sending one of the following in the parameter field with a SET command:

SRVC = ON

SRVC = OFF

RFL NCM

 

RFL Electronics Inc.

November 6, 2007

42

(973) 334-3100

Image 42
Contents RFL NCM DescriptionRFL NCM Specifications NMS Mode Ascii Character Addressing FormatInstallation RFL NCM MA-402I Module adapter, connector pinouts MA-485 Module adapter, jumper functions and TB1 pinouts MA-490 RFL NCM Front Panel View of RFL NCM, Network Communications Module Typical network example with all nodes having an NCM module At node 3, SW7 is set as follows Controls and indicators, RFL NCM Module Name/Description Function RFL NCM PRA Actel probe a NMS NMSDown SW2-3 SW2-4 Do not move SW10-4 Block diagram, RFL NCM module Functional DescriptionSystem Overview RX Output Ports NCM Backplane and Power ConnectionsTX Input Ports Logic Array Actel DesignSCB Module Application Modes and InterfacesUart Receive Section Uart Transmit Section T1 Transmit ModuleLOOP-BACKS T1 Receive ModuleRogue Control Baud and Clock GeneratorService LED should be illuminated green TestingPower indicator should be lit Test Equipment RequiredDS1 Power indicator should be lit DS1-B Equip OUT RXA LED should be illuminated red CH1 DS1-B Equip OUT CH2 Remote Control Using NMS NCM General Configurations and Status window for NodeTime Slot Module EnableE1 Signaling ModeTypical 3-node network using MA-485s 1 RS-485 port Bus a & Bus B Rogue DetectionNCM Address Configurations and Status window for Node Local CM AddressCM Address Passing Baud Rate Data Bits Parity Troubleshooting Port 2 EnableLoopback Remote Control Using SCL Commands Channel Card 3, Type 117 Under Remote Control Svce = onCodes Multiplexer Addresscard ADDRESSSETP1 = B00000011 Srvc = on Srvc = OFFCAS Setting BUS a SettingBUS B Setting Timeslot SelectionParity Settings Port Loopback SettingsBaud Settings Word Length SettingsApplication Mode CM Address Pass SettingsNMS Mode only SettingsCodes Port 1 Availability MUX Type & Configuration StatusType ID Port 2 AvailabilityPort 1 Application Status Application Configuration StatusCM Addressing Support Port 2 Application StatusRXA Remote CM Address Current Actel REVPort 1 INPUT/OUTPUT Status Port 2 INPUT/OUTPUT StatusTXA/RXB Status for T1/E1 TXB/RXA Status for T1/E1Powerville Road