ELECTRONIC SHUTTER

Using trigger pulse width

Set DIP switches 1 to 4 on the rear panel to 0.

An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2 μsec to 250 msec.

Switch

Mode 1

Mode 2

(Non-reset mode)

(Reset mode)

 

 

 

 

1

0

0

2

0

0

3

0

0

4

0

0

5

Frame: 0

/ Field: 1

6

0

0

7

1

0

8

1

1

9

0

0

0

0

0

Exposure time = Trigger pulse width + 97

μsec (EIA)

120

μsec (CCIR)

Note : 1. lt is recommended to set DIP switch 5 for field selection.

(The field selection is about two times in sensitivity as high as the frame selection.)

2.After a trigger pulse is input, a new trigger pulse must not be input before the video signal obtained by the trigger pulse has been output.

1:ON

0:OFF

Specifications of trigger pulse

T

A:4 to 5.0 V

B:0 to 1.0 V

T:2 s to 1/4 s

A

B

T: 2 μs to 1/4 s, 100 μs to 1/4 s when setting the shutter speed using DIP switch

*Input impedance: 10 kW or more

*The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.

9

Image 11
Contents User’s Table of Contents Outline Main FeaturesSpecifications Comparison System ConfigurationMain Specifications Connection Diagram Camera mounting reference hole Top Volume control switchLocation of Parts and Operation Lens mount section C mountFor Restart Reset RR/external trigger shutter Phase Conditions of External SynchronizationExternal synchronization for each mode Phase conditionsNormal shutter DIP switch on the rear panelSetting of normal shutter speed Electronic Shutter∙ Using DIP switch on the rear panel ∙ Mode 1 Non-reset mode∙ Mode 2 Reset mode Setting of external trigger shutter speedSpecifications of trigger pulse ∙ Using trigger pulse widthSpecifications of WEN Write ENable Pulse Example 1 of Long exposure Restart Reset R.RLong exposure ∙ Timing and conditionsExample 2 of long exposure Restart Reset R.RFrame Image Output with Strobe Light Timing chart by restart/resetTiming chart of horizontal output waveform Output Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIAOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Camera video output signal Typical value Even field 312.5 H 305 H 578+579 580+581 579+580 581+582 Sensor Read Clock Timing Chart Sensor Read Clock Timing Chart XC-EI30 XC-EI50 ∙ Continuous HD/VD input For setting the shutter speed using TRG widthHD/VD input ∙ Continuous HD input and single VD input No HD/VD input Internal synchronization Continuous HD/VD input For setting the shutter speed using DIP switchHD/VD input ∙ Continuous HD input and single VD input T = Under 10 ms T = 10 ms or more Reset Mode Timing Chart of External Trigger Shutter Mode 2 Reset Mode Dimensions Typycal Value Spectral Response CharacteristicsSpectral Response Characteristics XC-EI30 XC-EI50 List of C-Mount Lens Various Lens SelectionXC-E series XC-ES50/50CE XC-ES30/30CE XC-EI50/50CE XC-EI30/30CE