Sony XC-ES50/50CE manual No HD/VD input Internal synchronization

Page 26

XC-E series

TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)

For setting the shutter speed using TRG width

No HD/VD input (Internal synchronization)

 

 

 

 

 

 

 

Mode transition state

 

 

 

 

 

 

 

 

 

 

External input

External trigger

 

 

 

 

 

 

 

*3 Normal operation

inhibition area

 

 

 

External trigger shutter operation

(50 ms)

shutter operation

 

1

2

 

 

 

 

 

3

 

 

*1

Trigger

 

 

 

 

*3 Trigger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*2 Exposure time Te

*2 Exposure time Te

 

 

 

*2 Exposure

 

 

 

 

 

 

 

 

 

time Te

 

*4

Interrnal VD

 

 

 

 

 

 

 

 

 

 

 

 

*

5

 

*

5

T : T = Under 10

s

 

 

 

 

T : T = 10 s or more

 

 

Video out

1

 

2

 

 

 

 

3

 

WEN

 

 

 

 

*6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250H (XC-ES50/ES30, XC-EI50/EI30)

 

 

 

 

 

 

 

293H (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)

 

 

 

 

 

*1: *2:

*3:

*4: *5:

*6:

This is a signal input from the outside.

Exposure time Te Te = Trigger width + 97 μs (XC-ES50/ES30, XC-EI50/EI30),

Te = Trigger width + 120 μs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)

The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During the trigger inhibit period, an input trigger may be missed.

An internal VD signal is output by setting the INT/EXT switch on the rear panel to INT.

During external trigger shutter operation, an image is output when an internal VD signal falls after a trigger pulse falls (as shown by 1 and 2 in the figure). However, if the time (T in the figure) between the falling edges of a trigger pulse and internal VD signal is under 10 μs, an image is output when the internal VD signal or the next internal VD signal falls (as shown by 3 in the figure). (In this case, an image is output when the next internal VD signal falls.) An image and WEN signal are always output together. For more details, refer to the WEN signal. (The falling edge of an internal VD signal is the same in phase as the beginning of an equalizing pulse in a SYNC V area.)

When the external trigger shutter mode changes into the normal operation mode, one WEN signal is output.

Note : An image is superimposed when the next exposure ends before the previous image is output.

24

Image 26
Contents User’s Table of Contents Main Features OutlineSystem Configuration Specifications ComparisonMain Specifications Connection Diagram Lens mount section C mount Volume control switchLocation of Parts and Operation Camera mounting reference hole TopPhase conditions Phase Conditions of External SynchronizationExternal synchronization for each mode For Restart Reset RR/external trigger shutterElectronic Shutter DIP switch on the rear panelSetting of normal shutter speed Normal shutterSetting of external trigger shutter speed ∙ Mode 1 Non-reset mode∙ Mode 2 Reset mode ∙ Using DIP switch on the rear panel∙ Using trigger pulse width Specifications of trigger pulseSpecifications of WEN Write ENable Pulse ∙ Timing and conditions Restart Reset R.RLong exposure Example 1 of Long exposureRestart Reset R.R Example 2 of long exposureTiming chart by restart/reset Frame Image Output with Strobe LightOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Timing chart of horizontal output waveformOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Camera video output signal Typical value Even field 312.5 H 305 H 578+579 580+581 579+580 581+582 Sensor Read Clock Timing Chart Sensor Read Clock Timing Chart XC-EI30 XC-EI50 ∙ Continuous HD/VD input For setting the shutter speed using TRG widthHD/VD input ∙ Continuous HD input and single VD input No HD/VD input Internal synchronization For setting the shutter speed using DIP switch Continuous HD/VD inputHD/VD input ∙ Continuous HD input and single VD input T = Under 10 ms T = 10 ms or more Reset Mode Timing Chart of External Trigger Shutter Mode 2 Reset Mode Dimensions Spectral Response Characteristics Typycal ValueSpectral Response Characteristics XC-EI30 XC-EI50 Various Lens Selection List of C-Mount LensXC-E series XC-ES50/50CE XC-ES30/30CE XC-EI50/50CE XC-EI30/30CE