MAIN SPECIFICATIONS

Image pickup device

XC-ES50/50CE, XC-EI50/50CE:

1/2-inch interline transfer CCD

XC-ES30/30CE, XC-EI30/30CE:

1/3-inch interline transfer CCD

Number of effective pixels

XC-ES50/EI50, XC-ES30/EI30: 768 (H)x494 (V)

XC-ES50CE/EI50CE, XC-ES30CE/EI30CE: 752 (H)x582 (V)

CCD horizontal driving frequency

XC-ES50/EI50, XC-ES30/EI30:

14.318 MHz

XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:

14.187 MHz

CCD vertical driving frequency

XC-ES50/EI50, XC-ES30/EI30:

 

15.734 kHz

XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:

 

15.625 kHz

Signal system

EIA/CCIR

Cell size

 

 

 

XC-ES50/EI50:

 

8.4

(H)x9.8 (V) μ m

XC-ES50CE/EI50CE:

8.6

(H)x8.3 (V) μ m

XC-ES30/EI30:

 

6.35 (H)x7.4 (V) μ m

XC-ES30CE/EI30CE:

6.5

(H)x6.25 (V) μ m

Lens mount

C-mount

Flange back

17.526 mm

Synchronization system Internal/external (Selected automatically)

External sync input/output

HD/VD (2 to 5 Vp-p)

*Automatically selected according to the existence of an input signal

when the selection switch on the rear panel is set to EXT.

Allowable frequency deviation of external synchronization

±1 %

 

(in horizontal synchronous frequency)

Jitter

Within ± 50 nsec

Scanning system

2:1 interlacing

 

 

Non-interlacing

 

 

(during external sync input)

Horizontal resolution

 

XC-ES50/EI50, XC-ES30/EI30:

570 TV lines

XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:

560 TV lines

XC-E series

Sensitivity

 

XC-ES50/50CE:

400 lx F5,6 (γ =ON, MIN Gain,

 

without IR cut filter)

XC-ES30/30CE:

400 lx F4 (γ =ON, MIN Gain,

 

without IR cut filter)

XC-EI50/50CE:

400 lx F11 (γ =OFF, MIN Gain,

 

without IR cut filter)

XC-EI30/30CE:

400 lx F8 (γ =ON, MIN Gain,

 

without IR cut filter)

S/N ratio

60dB

Minimum illuminance

XC-ES50/50CE, XC-ES30/30CE:

0.3lx (F1.4 γ =ON, MAX Gain, without IR cut filter)

XC-EI50/50CE: 0.1 lx (F1.4 γ =ON, MAX Gain, without IR cut filter)

XC-EI30/30CE: 0.2 lx (F1.4 (γ =ON, MAX Gain, without IR cut filter)

Gain

AGC/Manual (Can be selected using

 

the switch on the rear panel.)

Gamma correction

ON/OFF (Can be selected

 

 

using the switch on the rear

 

 

panel.)

Electronic shutter

XC-ES50/EI50, XC-ES30/EI30:

1/100 to 1/10,000 seconds XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:

1/120 to 1/10,000 seconds

External trigger shutter

XC-ES50/EI50, XC-ES30/EI30:

1/4 to 1/10,000 seconds

XC-ES50CE/EI50CE, XC-ES30CE/EI30CE: 1/4 to 1/8,000 seconds

*Set using the DIP switch on the rear panel, or variable with the trigger pulse width.

Supply voltage

+12 VDC (+9.0V to 16V)

Power consumption

 

 

XC-ES30/30CE, XC-EI30/30CE:

1.4W

XC-ES50/50CE, XC-EI50/50CE:

1.6W

Operating temperature

–5 ˚C to +45 ˚C

 

Storage temperature

–20 ˚C to +60 ˚C

 

Performance assurance temperature

0 ˚C to +30 ˚C

Operating humidity 20 to 80 % (Non-condensing)

Storage humidity 20 to 95 % (Non-condensing) Vibration resistance 10G (For 20 minutes in the X, Y, and Z directions at 20 to 200 Hz)

3

Image 5
Contents User’s Table of Contents Outline Main FeaturesSpecifications Comparison System ConfigurationMain Specifications Connection Diagram Location of Parts and Operation Volume control switchLens mount section C mount Camera mounting reference hole TopExternal synchronization for each mode Phase Conditions of External SynchronizationPhase conditions For Restart Reset RR/external trigger shutterSetting of normal shutter speed DIP switch on the rear panelElectronic Shutter Normal shutter∙ Mode 2 Reset mode ∙ Mode 1 Non-reset modeSetting of external trigger shutter speed ∙ Using DIP switch on the rear panelSpecifications of trigger pulse ∙ Using trigger pulse widthSpecifications of WEN Write ENable Pulse Long exposure Restart Reset R.R∙ Timing and conditions Example 1 of Long exposureExample 2 of long exposure Restart Reset R.RFrame Image Output with Strobe Light Timing chart by restart/resetTiming chart of horizontal output waveform Output Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIAOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Camera video output signal Typical value Even field 312.5 H 305 H 578+579 580+581 579+580 581+582 Sensor Read Clock Timing Chart Sensor Read Clock Timing Chart XC-EI30 XC-EI50 ∙ Continuous HD/VD input For setting the shutter speed using TRG widthHD/VD input ∙ Continuous HD input and single VD input No HD/VD input Internal synchronization Continuous HD/VD input For setting the shutter speed using DIP switchHD/VD input ∙ Continuous HD input and single VD input T = Under 10 ms T = 10 ms or more Reset Mode Timing Chart of External Trigger Shutter Mode 2 Reset Mode Dimensions Typycal Value Spectral Response CharacteristicsSpectral Response Characteristics XC-EI30 XC-EI50 List of C-Mount Lens Various Lens SelectionXC-E series XC-ES50/50CE XC-ES30/30CE XC-EI50/50CE XC-EI30/30CE