Sony XC-ES50/50CE manual Reset Mode

Page 30

XC-E series

TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2

(RESET MODE)

For setting the shutter speed using TRG width

 

 

 

Mode transition state

 

 

 

External input

External trigger

 

 

*3 Normal operation

inhibition area

 

External trigger shutter operation

(50 ms)

shutter operation

 

1

 

 

2

*1 Trigger

 

*3 Trigger

 

 

 

 

 

 

 

*2 Exposure time Te

 

 

*2 Exposure

 

 

 

 

time Te

Video out

1

 

 

2

 

*4 1H to 2H

 

 

*4 1H to 2H

WEN

 

 

 

 

 

 

 

 

250H

250H

 

250H

 

(XC-ES50/ES30,

(XC-ES50/ES30,

 

(XC-ES50/ES30,

 

XC-EI50/EI30)

XC-EI50/EI30)

 

XC-EI50/EI30)

 

293H

293H

 

293H

 

(XC-ES50CE/ES30CE,

(XC-ES50CE/ES30CE,

 

(XC-ES50CE/ES30CE,

 

XC-EI50CE/EI30CE)

XC-EI50CE/EI30CE)

 

XC-EI50CE/EI30CE)

*1:

*2:

*3:

*4: *5:

This is a signal input from the outside. The trigger interval should be trigger pulse width + 1 field + 2H period or more. The trigger interval shorter than described above cannot be ensured. If a trigger pulse is not input under the prescribed conditions, the normal operation is ensured several V after a change in input operation under the prescribed conditions.

Exposure time Te Te = Trigger width + 97 μs (XC-ES50/ES30, XC-EI50/EI30),

Te = Trigger width + 120 μs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE) (The trigger width should be between 2 μs and 1/4 s)

The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During the trigger inhibit period, an input trigger may be missed.

A VD signal is generated 1H to 2H after a trigger pulse falls, and an image is output in synchronization with the VD signal.

When the external trigger shutter mode changes into the normal operation mode, a WEN signal is output.

28

Image 30
Contents User’s Table of Contents Main Features OutlineSystem Configuration Specifications ComparisonMain Specifications Connection Diagram Lens mount section C mount Volume control switchLocation of Parts and Operation Camera mounting reference hole TopPhase conditions Phase Conditions of External SynchronizationExternal synchronization for each mode For Restart Reset RR/external trigger shutterElectronic Shutter DIP switch on the rear panelSetting of normal shutter speed Normal shutterSetting of external trigger shutter speed ∙ Mode 1 Non-reset mode∙ Mode 2 Reset mode ∙ Using DIP switch on the rear panel∙ Using trigger pulse width Specifications of trigger pulseSpecifications of WEN Write ENable Pulse ∙ Timing and conditions Restart Reset R.RLong exposure Example 1 of Long exposureRestart Reset R.R Example 2 of long exposureTiming chart by restart/reset Frame Image Output with Strobe LightOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Timing chart of horizontal output waveformOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Camera video output signal Typical value Even field 312.5 H 305 H 578+579 580+581 579+580 581+582 Sensor Read Clock Timing Chart Sensor Read Clock Timing Chart XC-EI30 XC-EI50 For setting the shutter speed using TRG width HD/VD input∙ Continuous HD/VD input ∙ Continuous HD input and single VD input No HD/VD input Internal synchronization For setting the shutter speed using DIP switch Continuous HD/VD inputHD/VD input ∙ Continuous HD input and single VD input T = Under 10 ms T = 10 ms or more Reset Mode Timing Chart of External Trigger Shutter Mode 2 Reset Mode Dimensions Spectral Response Characteristics Typycal ValueSpectral Response Characteristics XC-EI30 XC-EI50 Various Lens Selection List of C-Mount LensXC-E series XC-ES50/50CE XC-ES30/30CE XC-EI50/50CE XC-EI30/30CE