Sony XC-ES50/50CE manual External trigger shutter, ∙ Mode 1 Non-reset mode, ∙ Mode 2 Reset mode

Page 10

XC-E series

ELECTRONIC SHUTTER

External trigger shutter

These modes are used to capture one image (one field) per trigger pulse.

Set DIP switches 6, 7, and 8 on the rear panel to mode 1 or 2. (Refer to the table below.)

When the trigger pulse width is 1/3 sec or more, the output signal is switched to a normal video signal.

There are two modes for timing in which a video signal is obtained.

Mode 1 (Non-reset mode)

In this mode, a video signal synchronized with a VD signal is output after a trigger pulse is input.

A video signal is synchronized with the external VD signal when an external HD/VD signal is input.

A video signal is synchronized with an internal VD signal when no external HD/VD signal is input.

Mode 2 (Reset mode)

In this mode, an internal video signal is output from a trigger pulse after a certain period of time. Video sync is always fixed with odd field for XC-ST70 and even field for XC-ST70CE.

*For more details of each timing chart, refer to pages 16 to 23.

Setting of external trigger shutter speed

There are two ways to set the shutter speed.

Mode 1 (Non-reset mode)

Switch

*1/100

1/125

1/250

1/500

1/1000

1/2000

1/4000

**1/10000

 

 

 

 

 

 

 

 

 

1

1

0

1

0

1

0

1

2

0

1

1

0

0

1

1

3

0

0

0

1

1

1

1

4

1

0

0

0

0

0

0

0

5

 

 

 

Frame: 0

/ Field: 1

 

 

 

6

0

0

0

0

0

0

0

0

7

1

1

1

1

1

1

1

1

8

1

1

1

1

1

1

1

1

9

0

Mode 2 (Reset mode)

Switch

*1/100

1/125

1/250

1/500

1/1000

1/2000

1/4000

**1/10000

 

 

 

 

 

 

 

 

 

1

1

0

1

0

1

0

1

2

0

1

1

0

0

1

1

3

0

0

0

1

1

1

1

4

1

0

0

0

0

0

0

0

5

 

 

 

Frame: 0

/ Field: 1

 

 

 

6

0

0

0

0

0

0

0

0

7

0

0

0

0

0

0

0

0

8

1

1

1

1

1

1

1

1

9

0

*The external trigger shutter speed is set to 1/100 sec for XC-ES50/ES30, XC-EI50/EI30 (EIA) and 1/120 sec for XC-ES50CE/ES30CE,

XC-EI50CE/EI30CE (CCIR).

**The external trigger shutter speed is set to 1/10000 sec for XC-ES50/ES30, XC-EI50/EI30 (EIA) and 1/8000 sec for XC-ES50CE/ES30CE, XC-EI50CE/EI30CE (CCIR).

1:ON

0:OFF –: Any

Using DIP switch on the rear panel

8

Image 10
Contents User’s Table of Contents Main Features OutlineSystem Configuration Specifications ComparisonMain Specifications Connection Diagram Lens mount section C mount Volume control switchLocation of Parts and Operation Camera mounting reference hole TopPhase conditions Phase Conditions of External SynchronizationExternal synchronization for each mode For Restart Reset RR/external trigger shutterElectronic Shutter DIP switch on the rear panelSetting of normal shutter speed Normal shutterSetting of external trigger shutter speed ∙ Mode 1 Non-reset mode∙ Mode 2 Reset mode ∙ Using DIP switch on the rear panel∙ Using trigger pulse width Specifications of trigger pulseSpecifications of WEN Write ENable Pulse ∙ Timing and conditions Restart Reset R.RLong exposure Example 1 of Long exposureRestart Reset R.R Example 2 of long exposureTiming chart by restart/reset Frame Image Output with Strobe LightOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Timing chart of horizontal output waveformOutput Waveform Timing Chart XC-ES50/EI50/ES30/EI30EIA Camera video output signal Typical value Even field 312.5 H 305 H 578+579 580+581 579+580 581+582 Sensor Read Clock Timing Chart Sensor Read Clock Timing Chart XC-EI30 XC-EI50 HD/VD input For setting the shutter speed using TRG width∙ Continuous HD/VD input ∙ Continuous HD input and single VD input No HD/VD input Internal synchronization For setting the shutter speed using DIP switch Continuous HD/VD inputHD/VD input ∙ Continuous HD input and single VD input T = Under 10 ms T = 10 ms or more Reset Mode Timing Chart of External Trigger Shutter Mode 2 Reset Mode Dimensions Spectral Response Characteristics Typycal ValueSpectral Response Characteristics XC-EI30 XC-EI50 Various Lens Selection List of C-Mount LensXC-E series XC-ES50/50CE XC-ES30/30CE XC-EI50/50CE XC-EI30/30CE