Pelco IS90 manual Surface Installation 4S Standard Electrical BOX

Page 15

6.Attach the back box to the mounting surface:

If you have access behind the ceiling/wall (refer to Figure 6 on page 13):

(1)Place the adapter plate on the inside of the ceiling/wall.

(2)Attach the back box to the ceiling/wall with two 10-32 x 1.50-inch Phillips pan head self-tapping screws (supplied).

If you do not have access behind the ceiling/wall access, use 3-16 toggle bolts (not supplied; refer to Figure 8).

BACK

BOX

CEILING/

WALL

3-16 TOGGLE BOLTS

(NOT SUPPLIED)

Figure 8. In-Ceiling Installation to a Fixed Ceiling/Wall

SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX

1.Attach the adapter plate (supplied) to the 4S box with two 8-32 x 1.00-inch Phillips pan head screws (supplied; refer to Figure 9 on page 16).

2.Pull the video and power wires through the adapter plate.

3.Connect the video cable and wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

4.Connect the power wires (refer to Table D).

Table D. Power Input: Surface, 4S Standard Electrical Box Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

C3425M-E (1/09)

15

Image 15
Contents IS90 Series Camclosure Page Contents List of Illustrations Radio and Television Interference Regulatory NoticesModels DescriptionIS90B-DNV9 IS90B-DNV9X Parts ListShown Actual Size Removing the Bubble Remove the BubbleInstallation Surface Installation CEILING/WALLUnshielded Twisted Pair UTP Video Ceiling/ Wall Installation Removing the Surface Mount Ring from the Back Box IN-CEILING Installation Suspended CeilingCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL In-Ceiling Installation to a Fixed Ceiling/Wall Surface Installation 4S Standard Electrical BOXStandard Electrical Box Installation IN-CEILING Installation 4S Deep Electrical BOXDeep Electrical Box Installation Varifocal Lens Zoom and Focus Adjustments Camera AdjustmentsAdjusting the Focus Switch Settings DN/CH/C Series AdjustmentsAuto Iris Level Adjustment Blemish Detection DAY/NIGHT Operation SW1-2 Line Sync DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 Auto White Balance/Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstalling the Bubble Install Liner and BubbleService Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug General SpecificationsCAMERA/LENS Revision History Product Warranty and Return Information