4.Remove an adjacent ceiling tile to access the unit.

5.Connect the video cable and wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

6.Connect the power wires (refer to Table B).

Table B. Power Input: In-Ceiling, Suspended Ceiling Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

7. Reinstall the adjacent ceiling tile.

IN-CEILING INSTALLATION: FIXED CEILING/WALL

1.Remove the surface mount ring from the back box (refer to Figure 5 on page 12):

a.Place your fingers on the circular marks located on the sides of the surface mount ring.

b.Pinch the sides.

c.Lift and remove the surface mount ring from the back box. Do not discard the surface mount ring, it is required to complete the installation.

2.Cut a hole 4 inches (10 cm) in diameter in the ceiling/wall (refer to Figure 8 on page 15).

3.Pull the video and power wires through the opening.

4.Connect the video cable and wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

5.Connect the power wires (refer to Table C).

Table C. Power Input: In-Ceiling, Fixed Ceiling/ Wall Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

14

C3425M-E (1/09)

Image 14
Contents IS90 Series Camclosure Page Contents List of Illustrations Regulatory Notices Radio and Television InterferenceDescription ModelsParts List IS90B-DNV9 IS90B-DNV9XShown Actual Size Remove the Bubble Removing the BubbleUnshielded Twisted Pair UTP Video InstallationSurface Installation CEILING/WALL Ceiling/ Wall Installation IN-CEILING Installation Suspended Ceiling Removing the Surface Mount Ring from the Back BoxCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL Surface Installation 4S Standard Electrical BOX In-Ceiling Installation to a Fixed Ceiling/WallIN-CEILING Installation 4S Deep Electrical BOX Standard Electrical Box InstallationDeep Electrical Box Installation Camera Adjustments Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus DN/CH/C Series Adjustments Switch SettingsAuto Iris Level Adjustment Blemish Detection DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-2 Line SyncSW1-4 Auto White Balance/Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Liner and Bubble Installing the BubbleService Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Specifications GeneralCAMERA/LENS Revision History Product Warranty and Return Information