Pelco IS90 manual Camera Adjustments, Varifocal Lens Zoom and Focus Adjustments

Page 18

Camera Adjustments

To perform the following camera adjustments, connect a monitor. Then turn on power to the camera and monitor. To use the service connector, refer to Service Connector on page 30.

To set the DIP switches or to adjust the auto iris level (DN, CH, or C) or the vertical phase (DW or CW), you will need a miniature trimpot adjustment tool with a 0.05-inch (1.27 mm) blade. Suggested tools include a miniature flat-tip screwdriver, a Philmore trimpot tool (#63-8608), and the Philmore 10-piece tool set (#63-910). To adjust the lens, you may also need a miniature Phillips screwdriver.

After you have adjusted the unit, install the bubble and liner (if necessary).

VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS

NOTE: You will need a miniature Phillips or flat-tip screwdriver to loosen and tighten the locking screws.

To adjust the field of view:

1.Loosen the zoom locking screw (refer to Figure 11).

2.Turn the zoom adjustment ring clockwise or counterclockwise to select the field of view.

3.Tighten the zoom locking screw.

FOCUS

ZOOM

Figure 11. Location of Zoom and Focus Locking Screws

18

C3425M-E (1/09)

Image 18
Contents IS90 Series Camclosure Page Contents List of Illustrations Regulatory Notices Radio and Television InterferenceDescription ModelsParts List IS90B-DNV9 IS90B-DNV9XShown Actual Size Remove the Bubble Removing the BubbleInstallation Surface Installation CEILING/WALLUnshielded Twisted Pair UTP Video Ceiling/ Wall Installation IN-CEILING Installation Suspended Ceiling Removing the Surface Mount Ring from the Back BoxCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL Surface Installation 4S Standard Electrical BOX In-Ceiling Installation to a Fixed Ceiling/WallIN-CEILING Installation 4S Deep Electrical BOX Standard Electrical Box InstallationDeep Electrical Box Installation Camera Adjustments Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus DN/CH/C Series Adjustments Switch SettingsAuto Iris Level Adjustment Blemish Detection DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-2 Line SyncSW1-4 Auto White Balance/Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Liner and Bubble Installing the BubbleService Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Specifications GeneralCAMERA/LENS Revision History Product Warranty and Return Information