Pelco IS90 manual Auto Iris Level Adjustment

Page 21

SW4-4: Flickerless

In certain lighting conditions, a flicker in the light source may affect camera operation. Flickering can be caused by a number of conditions, including the quality of the source power and the age and type of fluorescent bulbs and ballasts.

Set SW4-4 to ON to enable flickerless operation. The camera will remove the effects of flickering when present. The shutter speed will be set to 1/120 (NTSC) or 1/100 (PAL).

Set it to OFF to disable flickerless operation. This is the default.

NOTE: If you enable flickerless operation, you should use AC line lock for best results.

SW4-5: Auto White Balance/Manual White Balance

Auto white balance (AWB) is enabled by default (OFF).

To manually set and lock the white balance:

1.Set SW4-5 to OFF.

2.Hold a white background in front of the lens until the video shows all white.

3.While holding the background in place, set SW4-5 to ON. A blue blinking block appears on the video image for a few seconds. When the block changes to solid green, the manual white balance (MWB) process is complete.

SW4-6: Reserved

Do not change SW4-6 from its factory setting. SW4-6 must be set to OFF for varifocal models; it must be set to ON for fixed-iris lenses.

AUTO IRIS LEVEL ADJUSTMENT

To adjust the auto iris DC drive level (refer to Figure 13 on page 20):

1.Tilt or rotate the camera module until you can access the auto iris level control (R19).

2.Turn the screw clockwise to increase the brightness level or counterclockwise to decrease the brightness level.

VERTICAL PHASE ADJUSTMENT

Use this procedure for 24 VAC operation only.

When using more than one camera power supply, a brief vertical roll may occur on the monitor when switching from one camera to another. To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If the problem persists, adjust the phase control by synchronizing, or line-locking, the cameras to one another.

NOTE: When adjusting vertical phase, line sync (SW4-3) must be set to OFF for AC line lock.

Adjusting Vertical Phase

You may need two people when synchronizing the cameras: one person at the camera and the other at the monitor to observe the vertical roll and the effect of any camera adjustments.

To synchronize the cameras:

1.Choose a reference camera to which all other cameras will be phased.

2.Select the camera to synchronize. Use buttons SW1 and SW2 to synchronize the camera to the reference camera (refer to Figure 13 on page 20). SW1 increases vertical phase; SW2 decreases vertical phase.

C3425M-E (1/09)

21

Image 21
Contents IS90 Series Camclosure Page Contents List of Illustrations Radio and Television Interference Regulatory NoticesModels DescriptionIS90B-DNV9 IS90B-DNV9X Parts ListShown Actual Size Removing the Bubble Remove the BubbleInstallation Surface Installation CEILING/WALLUnshielded Twisted Pair UTP Video Ceiling/ Wall Installation Removing the Surface Mount Ring from the Back Box IN-CEILING Installation Suspended CeilingCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL In-Ceiling Installation to a Fixed Ceiling/Wall Surface Installation 4S Standard Electrical BOXStandard Electrical Box Installation IN-CEILING Installation 4S Deep Electrical BOXDeep Electrical Box Installation Varifocal Lens Zoom and Focus Adjustments Camera AdjustmentsAdjusting the Focus Switch Settings DN/CH/C Series AdjustmentsAuto Iris Level Adjustment Blemish Detection DAY/NIGHT Operation SW1-2 Line Sync DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 Auto White Balance/Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstalling the Bubble Install Liner and BubbleService Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug General SpecificationsCAMERA/LENS Revision History Product Warranty and Return Information