DN/CH/C SERIES ADJUSTMENTS

Refer to Figure 13 to adjust the IS90-DN, IS90-CH, or IS90-C model.

Figure 13. Adjusting the IS90-DN/CH/C Series Camclosure

SWITCH SETTINGS

Locate the DIP switch. Then set the switches for your installation.

SW4-1: Auto Gain Control

The automatic gain control (AGC) adjusts the image automatically to compensate for changes in light levels.

Set SW4-1 to ON to enable AGC. Set it to OFF to disable AGC. The default is ON.

SW4-2: Backlight Compensation

The backlight compensation (BLC) feature compensates for backlit scenes by enhancing objects in the center of the scene.

Set SW4-2 to ON to enable BLC. Use this setting if a bright backlight is present and the subject in the center of the picture appears dark or as a silhouette.

Set it to OFF to disable backlight compensation. This is the default.

SW4-3: Line Sync

When multiple cameras are connected to the same switching device, vertical roll may occur on the monitor. AC line lock eliminates vertical roll by locking the frame rate to the power supply frequency. Each camera output is synchronized to the power supply frequency (refer to Vertical Phase Adjustment on page 21 for more information.)

Internal line sync disables line lock and synchronizes cameras internally.

Set SW4-3 to OFF to use AC line lock.

Set it to ON to use internal line sync. The default is OFF.

20

C3425M-E (1/09)

Image 20
Contents IS90 Series Camclosure Page Contents List of Illustrations Regulatory Notices Radio and Television InterferenceDescription ModelsParts List IS90B-DNV9 IS90B-DNV9XShown Actual Size Remove the Bubble Removing the BubbleUnshielded Twisted Pair UTP Video InstallationSurface Installation CEILING/WALL Ceiling/ Wall Installation IN-CEILING Installation Suspended Ceiling Removing the Surface Mount Ring from the Back BoxCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL Surface Installation 4S Standard Electrical BOX In-Ceiling Installation to a Fixed Ceiling/WallIN-CEILING Installation 4S Deep Electrical BOX Standard Electrical Box InstallationDeep Electrical Box Installation Camera Adjustments Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus DN/CH/C Series Adjustments Switch SettingsAuto Iris Level Adjustment Blemish Detection DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-2 Line SyncSW1-4 Auto White Balance/Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Liner and Bubble Installing the BubbleService Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Specifications GeneralCAMERA/LENS Revision History Product Warranty and Return Information