JAI CV-A33CL operation manual Auto trigger Mode, Vertical timing for auto trigger function

Page 18

CV-A33CL

6.4.4. Auto trigger Mode

The auto trigger function, TR=3 can be used as sensing device inside the camera field of view. It sense in a programmable window from top of the image. The continuous output is sent to the frame grabber, which PC should be programmed to sense if an object is passing the window. The horizontal position and the signal threshold could be the programmed parameters. If an object passing is detected, a trigger is send to the camera. The resulting image, a full frame or windows scan, (depending of windows scan setting), is read out to the grabber, and the auto trigger function with fast scan of the programmed window will start again.

To use this mode:

 

 

Set function:

Trigger mode “Auto Trigger Mode”

TR=3

 

“Auto Trigger”

AT=3 through 493

 

“Windows” “Full” or “windows scan”

WS=0, WS=1

 

Polarity and other functions

 

PC and grabber:

Detect trigger conditions

 

 

Send a pulse width control trigger to the camera.

 

Input:

Ext. trigger to Camera Link or pin #10 on 12-pin connector.

Important notes on using this mode.

The exposure is equal the programmable parameter AT.

The exposure time is the same for the auto trigger partial scanned frame and the resulting triggered frame read out.

The duration of the trigger should be >1 LVAL to < 1 FVAL. (>16.8 sec. to <8.3 msec.)

Refer to 6.1.7. Auto Trigger Window of Interest.

Max auto trigger frame rate is 5403 fps.

1 FVAL per iod

11L

TRG

FVAL

LVAL

Exposure per iod

EEN

E ffec t ive P ixe ls

 

3L

4L

4L

DATAOUT

0 1 2

 

0 1 2

 

 

 

DVAL

0 1 2

0 1 2 3 4

When Trgger is inpu t.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 LVAL = 16.825s

 

 

 

1 FVAL per iod

 

 

 

 

 

 

 

502L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E ffec t ive L ines

493L

 

 

 

 

 

 

 

 

 

 

5L

4L

 

 

8

9

0

1 2

 

0 1 2

0 1 2

0 1 2

8

8

9

9

9

 

4 4

4

4

4

 

 

 

 

Fig. 23. Vertical timing for auto trigger function

- 17 -

Image 18
Contents CV-A33CL CV-A33CL Main Features GeneralStandard Composition Locations and Functions LocationsPin Multi-connector DC-IN/Trigger Digital Output Connector for Camera LinkPin Assignment Input and Output Circuits EEN outputCamera Link interface CV-A33 Camera Camera Link CableCmos Sensor Functions and OperationsBasic functions Pixel principleCmos Sensor principle diagram Column ProcessCV-A33 Cmos Sensor array Window of Interest Auto Trigger Window of InterestVertical timing Normal mode. Full frame Sensor layout and timingEffective image format Horizontal timing Normal mode. Full frameLval a-synchronous accumulation Lval a-synchronous accumulationTiming for window of interest Window of interestOutput of Timing Signals Input/Output of Timing SignalsInput of Timing Signals Trigger ModesEdge Pre-select Mode Continuous Operation Non triggeredVertical timing for edge pre-select min. exposure Pulse Width Control Mode Vertical timing for pulse width control min. exposureAuto trigger Mode Vertical timing for auto trigger functionConfiguring the Camera Switch setting insideOther Functions RS-232C control CV-A33CL command list Parameter RemarksCamera Control Tool for CV-A33 Window from camera control toolExternal Appearance and Dimensions SpecificationsSpectral sensitivity Specification table CV-A33CLPrecautions Typical Sensor CharacteristicsAppendix Users Mode Settings Users Modifications Users RecordCamera type