CV-A33CL 
7.3. CV-A33CL  command list
Command Name  | Format  | 
A – General settings and useful commands  | |
Parameter
Remarks
  | EB  | 
  | Echo Back  | [  | 
  | 
  | 
  | ]  | 
  | 
  | 
  | 0=Echo off  | 1=Echo on  | Off at power up  | 
  | 
  | EB= Param. <CR><LF>  | 
  | |||||||||||
  | ST  | 
  | Camera Status request  | ST?<CR><LF>  | 
  | 
  | 
  | 
  | Actual setting  | |||||
  | HP  | 
  | Online Help request  | HP?<CR><LF>  | 
  | 
  | 
  | Command list  | ||||||
  | VN  | 
  | Firmware version  | VN?<CR><LF>  | 
  | 
  | 
  | 3 letter version  | ||||||
  | ID  | 
  | Camera ID request  | ID?<CR><LF>  | 
  | 
  | 
  | 
  | 10 characters  | |||||
  | MD  | 
  | Model Name request  | MD?<CR><LF> | 
  | 
  | 
  | ≤ 10 characters  | ||||||
  | UD  | 
  | User ID (Free text)  | TR=[Param.]<CR><LF>  | User can save and load free text  | ≤ 16 characters  | ||||||||
  | 
  | B –  | Video Output  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | BA  | 
  | Output bit allocation  | BA=[Param.]<CR><LF>  | 0=10 bit  | 1=8 bit  | Camera Link  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
  | 
  | C –  | Timing and shutter related | commands | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
  | WS  | 
  | Windows Scan  | WS=[Param.]<CR><LF>  | 0=full frame  | 1=windows scan  | 
  | |||||||
  | WX  | 
  | X Scan start coordinate  | WX=[Param.]<CR><LF>  | 
  | Start pixel #  | ||||||||
  | WY  | 
  | Y Scan start coordinate  | 
  | [  | 
  | ]  | <CR><LF>  | 
  | Start line#  | ||||
  | 
  | WY= Param.  | 
  | 
  | 
  | |||||||||
  | WW  | 
  | X Scan size width  | 
  | 
  | [  | 
  | ]  | <CR><LF>  | 
  | Window width  | |||
  | 
  | WW= Param.  | 
  | 
  | 
  | |||||||||
  | WH  | 
  | Y Scan size height  | 
  | 
  | [  | 
  | 
  | ]  | 
  | 3 – 493  | 
  | Window height  | |
  | 
  | WH= | Param. <CR><LF>  | 
  | 
  | |||||||||
  | AT  | 
  | Auto Trigger  | AT=[Param.]<CR><LF>  | 
  | *)  | ||||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Wind. 3H to 493H  | 
  | TR  | 
  | Trigger mode  | TR=[Param.]<CR><LF>  | 0=normal  | 1=Edge   | 
  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 2=Pulse width  | 3=Auto Trigger  | 
  | 
  | SM  | 
  | Shutter mode  | SM=[Param.]<CR><LF>  | 0=Normal  | 1=Program. exp  | 
  | |||||||
  | SH  | 
  | Shutter speed  | SH=[Param.]<CR><LF>  | 0=Off (1/120)  | 1=1/250  | All 8 steps are  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 2=1/500  | 3=1/1000  | valid in normal  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 4=1/2000  | 5=1/5000  | trigger mode.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 6=1/10000  | 7=1/20000  | 
  | 
  | PE  | 
  | Programmable expos.  | [  | 
  | 
  | 
  | ]  | 
  | 
  | 
  | 
  | Exp. 1H to 492H  | |
  | 
  | PE=  | Param. <CR><LF>  | 
  | H= 16.8∝sec  | |||||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | D–  | Signals and polarity | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | LS  | 
  | LVAL synchronous accum.  | [  | 
  | 
  | 
  | ]  | 
  | 
  | 
  | 0= LVAL sync.  | 1= LVAL   | *1) Only   | 
  | 
  | LS= | Param. <CR><LF> | 
  | ||||||||||
  | TI  | 
  | Trigger Input  | TI=[Param.]<CR><LF>  | 0= CamerLink  | 1= 12 pin Hiror  | 
  | |||||||
  | 
  | 
  | 
  | [  | 
  | ]  | 
  | 
  | 
  | 
  | 
  | *2)  | ||
  | TP  | 
  | Trigger polarity  | TP= Param.  | <CR><LF>  | 0= active low  | 1= active high  | 
  | ||||||
  | E –  | Gain and analogue signals setting | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | BL  | 
  | Black level  | BL=[Param.]<CR><LF>  | 
  | |||||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | ||||||||
  | GA  | 
  | Gain level  | GA=[Param.]<CR><LF>  | 
  | |||||||||
  | CB  | 
  | Calibration of CMOS sensor  | CB=0<CR><LF>  | 0 is the only allowed parameter  | Will calibrate the  | ||||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | CMOS sensor  | 
  | F –  | Saving and loading data in EEPROM  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||||
  | LD  | 
  | Load settings from camera  | [  | 
  | 
  | ]  | 
  | 
  | 
  | 0=Factory data  | 1=User 1 area  | Latest used data  | |
  | 
  | LD=  | 
  | Param. <CR><LF>  | default at power  | |||||||||
  | 
  | 
  | EEPROM  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 2=User 2 area  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | up  | 
  | SA  | 
  | Save settings to camera  | SA=[Param.]<CR><LF>  | 1=User 1 area  | 2=User 2 area  | Parameter = 0 is  | |||||||
  | 
  | 
  | EEPROM  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | not allowed | 
*)  | 
  | Auto trigger window will always  | start from top. Max frame rate  | with AT=3. It is 2 LVAL exposure + 9 LVAL  | offset.  | |||||||||
*1)  | 
  | The command LS is found on the first cameras. Only LS=1 is will work correct.  | 
  | 
  | ||||||||||
*2)  | 
  | If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. TTL only.  | 
  | |||||||||||
!!Do not try to use commands not shown in this list.
- 20 -