Nikon XX152-02-00 specifications Mounting from Above the Ceiling, Safety Cord Installation

Page 15

2.If cables are used without the use of flexible conduit:

a.Remove the enclosure top by loosening the 3 screws. Remove the conduit fitting by loosening the nut and sliding it out. Install the supplied strain relief fitting in its place and re-attach the top cover.

b.Hold the enclosure near the hole in the ceiling and route cables through the strain relief fitting.

2.If cables are channeled through flexible cable:

a.Hold the enclosure near the hole in the ceiling and route conduit cables through the conduit fitting.

b.Insert the end of the flexible conduit pipe into the conduit fitting. Cable length should be flush with the bottom of the enclosure, approximately 12 in. (305 mm). Tighten the clamp screw.

3.Lift the enclosure up through the ceiling hole. Turn and tighten the flipper screws to obtain a flush fit with the ceiling plane.

4.Connect the enclosure’s safety cord clip to the tab in the camera mechanism to allow the drive to hang from the enclosure. Refer to Figure 2 for location of tab.

Continue with section on Cable Connections.

Figure 2

Safety Cord Installation

Mounting from Above the Ceiling

Use this method of installation if there is access to the space above. The ceiling material must provide suitable strength to support the weight of the SurveyorVFT fixed dome with the two flippers on the enclosure. Refer to the section on Optional Independent Support for installations requiring additional support. Be sure the area around the selected location is clear of obstacles (such as steel beams, headers, pipes, electrical wiring, etc.) that would interfere with mounting. Video, sync, and power cables must be routed to the location.

1.Mark with the scribe and cut a 7-3/8 in. (187 mm) hole in the ceiling at the desired location. Remove tile from dropped ceiling if necessary. Feed all necessary flexible conduit pipe or cables down through the hole.

2.Lift the SurveyorVFT enclosure up to the ceiling and snap it into the hole. Turn and tighten the flipper screws for a flush fit. Connect the enclosure’s safety cord clip to the tab in the camera mechanism to allow the mechanism to hang from the enclosure. Align the 2 slots on the camera mechanism with the tabs in the enclosure, being sure to match up the arrows on both the drive and in the enclosure. Insert the camera mechanism into the enclosure until it snaps into place.

XX152-02-00 Rev 1004 SurveyorVFT Fixed Camera Dome

Installation 5

Image 15
Contents Fixed Camera Dome XX152-02-00Page FCC Notice Graphic Symbol Explanation SafeguardsContents In-Ceiling No Access to Ceiling Quick InstallationIn-Ceiling Access to Ceiling Pendant Indoor Pendant Outdoor Page Models, Product Codes and Descriptions IntroductionInspection for Concealed Damage InstallationUnpacking and Inspection Inspection for Visible DamageEnclosure SurveyorVFT Fixed Dome ComponentsMounting the Unit In-Ceiling MountingUse of the Scribe Mounting from Above the Ceiling Safety Cord InstallationOptional Independent Support Installation of Optional In-Ceiling Mounting KitIndoor Pendant Twisted-Pair Video Cable Cable ConnectionsOutdoor Pendant Coaxial Video CableCamera Power Connections DIP Switch Settings Autoiris AdjustmentsCamera Synchronization Potentiometer/DIP Switch Location DIP Switch Settings Final Installation Camera/Lens Adjustments 5-50 mm Version ShownIn-Ceiling In-Ceiling Mount Final Installation Camera Mounting Bracket Adjustment 2.6-6 mm Version ShownPendant Mount Dome Final Installation Outdoor Pendant Disassembly In-Ceiling InstallationPendant Installation Operation MaintenanceCare and Cleaning of Lower Dome Fuse ReplacementShipping Instructions Inch Pipe Designation ReferenceBelden1721X 24, Solid Polyethylene Bare Copper 100 Wire DistancesTwisted-Pair Cable Twisted PairsTechnical Information Storage Temperature Range Dimensions In-CeilingWeight Operating TemperatureCamera Specifications Model Focal Length Field-of-View Horizontal Vertical Lens SpecificationsVicon Standard Equipment Warranty Far East Office Corporate HeadquartersVicon Europe Headquarters Brussels Office