Nikon XX152-02-00 specifications Camera Power Connections

Page 19

Camera Power Connections

Note: Vicon systems and components, like most electronic equipment, require a clean, stable power source. Voltage irregularities such as surges, drops, and interruptions can affect the operation of your equipment and, in severe cases, damage certain components. Vicon strongly recommends the use of line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems.

Power is connected through a two-position detachable screw terminal connector on the PC board (P8). Refer to Figure 4. Refer to Table 2 for the input power connections.

1.Find the detachable power cable connector supplied on the PC board.

2.Strip approximately 1 in. (25 mm) of insulation off power cables. Then strip off approximately 0.25 in. (6 mm) of insulation off each individual wire. Attach the camera power cables to the connector according to Table 2.

3.Press the cable connector onto the board connector. The connector is keyed to prevent incorrect installation.

The camera is shipped prepared for 24 VAC.

Figure 4

Camera/Lens PC Board

Table 2

Camera Power Connections

Pin Number

Function

1

24 VAC Input

2

24 VAC Return

XX152-02-00 Rev 1004 SurveyorVFT Fixed Camera Dome

Installation 9

Image 19
Contents Fixed Camera Dome XX152-02-00Page FCC Notice Graphic Symbol Explanation SafeguardsContents In-Ceiling No Access to Ceiling Quick InstallationIn-Ceiling Access to Ceiling Pendant Indoor Pendant Outdoor Page Models, Product Codes and Descriptions IntroductionInspection for Concealed Damage InstallationUnpacking and Inspection Inspection for Visible DamageEnclosure SurveyorVFT Fixed Dome ComponentsIn-Ceiling Mounting Mounting the UnitUse of the Scribe Mounting from Above the Ceiling Safety Cord InstallationOptional Independent Support Installation of Optional In-Ceiling Mounting KitIndoor Pendant Twisted-Pair Video Cable Cable ConnectionsOutdoor Pendant Coaxial Video CableCamera Power Connections Autoiris Adjustments DIP Switch SettingsCamera Synchronization Potentiometer/DIP Switch Location DIP Switch Settings Camera/Lens Adjustments 5-50 mm Version Shown Final InstallationIn-Ceiling In-Ceiling Mount Final Installation Camera Mounting Bracket Adjustment 2.6-6 mm Version ShownPendant Mount Dome Final Installation Outdoor Pendant In-Ceiling Installation DisassemblyPendant Installation Operation MaintenanceCare and Cleaning of Lower Dome Fuse ReplacementShipping Instructions Inch Pipe Designation ReferenceBelden1721X 24, Solid Polyethylene Bare Copper 100 Wire DistancesTwisted-Pair Cable Twisted PairsTechnical Information Storage Temperature Range Dimensions In-CeilingWeight Operating TemperatureCamera Specifications Model Focal Length Field-of-View Horizontal Vertical Lens SpecificationsVicon Standard Equipment Warranty Far East Office Corporate HeadquartersVicon Europe Headquarters Brussels Office