Nikon XX152-02-00 specifications Outdoor Pendant

Page 25

Outdoor Pendant

After all the cabling is complete, push the SurveyorVFT camera mechanism straight up into the housing. Align the 2 slots on the camera drive with the tabs in the enclosure, being sure to match up the arrows on both the drive and in the enclosure. Insert the camera drive into the enclosure until it snaps into place.

Note: Assure that there is no extra slack in the cabling that will interfere with proper installation and operation. Push any extra cabling up into the mount or pipe.

After the SurveyorVFT is in place, the camera lens can be adjusted. The camera position can be adjusted horizontally and vertically and rotation about the lens axis (roll). With the camera powered on and video displayed in a monitor, turn the camera to point in the desired direction. The tilt position can also be adjusted. Loosen the two nuts, if necessary, on either side of the camera mounting frame (use an open end 11/32 wrench). Position the camera and retighten nuts. The camera mounting bracket position can be adjusted relative to the closeness to the dome by loosening the lock nuts and changing the vertical position of the camera mounting frame within the slots in the mounting bracket. Refer to Figure 8.

The lens can be manually adjusted. On the 5-50 mm lens, the telephoto/wide adjustment is the front ring, iris (open and close) is the middle ring and focus (near to infinity) is the end ring. On the 2.6-6 mm lens, focus (near to infinity) is the front ring and the telephoto/wide adjustment is the end ring; iris is fixed. Refer to Figure 7. On autoiris lenses, a potentiometer is provided for iris adjustment.

After the camera/lens is properly adjusted, the lower dome can be installed. Lift the lower dome up to the SurveyorVFT and insert the clip of the safety cord from the lower dome into the hole provided on the inside of the housing to anchor the lower dome. See label inside housing. Holding the lower dome, align the two (2) molded tabs on the lower dome with the recesses on the inner enclosure. Press the lower dome into the SurveyorVFT and verify that it snaps into place on both sides. Tighten the four (4) trim ring screws to hold the lower dome in place. Refer to Figure 10.

XX152-02-00 Rev 1004 SurveyorVFT Fixed Camera Dome

Installation 15

Image 25
Contents Fixed Camera Dome XX152-02-00Page FCC Notice Graphic Symbol Explanation SafeguardsContents In-Ceiling No Access to Ceiling Quick InstallationIn-Ceiling Access to Ceiling Pendant Indoor Pendant Outdoor Page Models, Product Codes and Descriptions IntroductionUnpacking and Inspection InstallationInspection for Visible Damage Inspection for Concealed DamageEnclosure SurveyorVFT Fixed Dome ComponentsIn-Ceiling Mounting Mounting the UnitUse of the Scribe Mounting from Above the Ceiling Safety Cord InstallationOptional Independent Support Installation of Optional In-Ceiling Mounting KitIndoor Pendant Outdoor Pendant Cable ConnectionsCoaxial Video Cable Twisted-Pair Video CableCamera Power Connections Autoiris Adjustments DIP Switch SettingsCamera Synchronization Potentiometer/DIP Switch Location DIP Switch Settings Camera/Lens Adjustments 5-50 mm Version Shown Final InstallationIn-Ceiling In-Ceiling Mount Final Installation Camera Mounting Bracket Adjustment 2.6-6 mm Version ShownPendant Mount Dome Final Installation Outdoor Pendant In-Ceiling Installation DisassemblyPendant Installation Care and Cleaning of Lower Dome MaintenanceFuse Replacement OperationShipping Instructions Inch Pipe Designation ReferenceTwisted-Pair Cable Wire DistancesTwisted Pairs Belden1721X 24, Solid Polyethylene Bare Copper 100Technical Information Weight Dimensions In-CeilingOperating Temperature Storage Temperature RangeCamera Specifications Model Focal Length Field-of-View Horizontal Vertical Lens SpecificationsVicon Standard Equipment Warranty Vicon Europe Headquarters Corporate HeadquartersBrussels Office Far East Office