Lamps
Clearing document jams
Adjusting the separator module tension
The scanner has a lamp saver feature to prolong lamp life. The lamps shut off after five minutes of scanner idle time.
1.Remove any documents from the feeder area.
2.Lift up the scanner door release to unlatch the scanner door.
3.Pull up to open the scanner door.
4.Locate the jammed document and remove it.
5.Lower the scanner door and press it down firmly until it latches into place.
Most documents will feed perfectly fine with the default separator module tension. However, there may be times when you are scanning documents that are lighter or heavier than normal. Two additional positions for the separator module spring allow you to adjust the tension to improve the scanning of these types of documents. The spring can be placed in one of the two channels or it can be released and left on the flat surface.
Heavy documents | Normal documents | Light documents |
| (default position) |
|
1.Power down the scanner.
2.Remove any documents from the feeder area.
3.Lift up the scanner door release to unlatch the scanner door.
4.Pull up to open the scanner door.
5.Remove the separator module by pulling it down and lifting it off.
6.Pull the spring gently into the position you want.
7.Insert the separator module and align the shaft ends.
8.Press until the separator module clicks into place.
9.Lower the scanner door and press it down firmly until it latches into place.
| 29 |