Ricoh FV-G030B1 manual 31/37

Page 31

Command No.

 

 

 

 

 

 

 

Command Description

2BH: [7..0]

 

[Weight3 for ALC] Initial data: 1AH

 

 

 

 

 

 

 

Sets the weight for ALC weight area 5 and 6.

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

D4

D3

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

Weight for ALC weight area 6

1

Range: 0 to 15

 

 

D3 to D0:

Weight for ALC weight area 5

10

Range: 0 to 15

 

 

*Please set the ALC weight area with “30H to 3FH”

 

 

 

 

 

 

 

 

 

2CH: [7..0]

 

[Weight4 for ALC] Initial data: 11H

 

 

 

 

 

 

 

Sets the weight for ALC weight area 7 and 8.

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

D4

D3

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

Weight for ALC weight area 8

1

Range: 0 to 15

 

 

D3 to D0:

Weight for ALC weight area 7

1

Range: 0 to 15

 

 

*Please set the ALC weight area with “30H to 3FH”

 

 

 

 

 

 

 

 

 

2DH: [7..0]

 

[Weight5 for ALC] Initial data: 01H

 

 

 

 

 

 

 

Sets the weight for ALC weight area 9.

 

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

D4

D3

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

No Function

 

 

 

Always set as “0000”

 

 

D3 to D0:

Weight for ALC weight area 9

1

Range: 0 to 15

 

 

*Please set the ALC weight area with “30H to 3FH”

 

 

 

 

2EH: [7..0]

 

[Target Brightness for ALC] Initial data: 128, data range: 0 to 255

 

 

Sets the target brightness for the ALC function (AGC, auto shutter or iris lens auto control).

 

 

 

 

2FH: [7..0]

 

[ALC peak-average] Initial data: 0, data range: 0 to 255

 

 

 

Sets the control standard for the ALC function (AGC, auto shutter or iris lens auto control)

 

 

When set as 0 (Average: 100%, Peak: 0%), the ALC function with the average brightness of the photometry area.

 

 

When set as 255 (Average: 0%, Peak: 100%), the ALC function with the peak brightness of the photometry area.

 

 

 

 

 

 

 

 

 

 

 

 

FV-G030B1

31/37

User’s Guide Rev. 1.01

 

Image 31
Contents FV-G030B1 User’s Guide Rev GigE Vision VGA Monochrome CCD Camera FV-G030B1Table of Contents RJ45 Connector Connector SpecificationsPower-I/O Connector DC Iris Lens ConnectorFV-G030B1 User’s Guide Rev IOOut Equivalent Circuit for the Input Pin of the I/O ConnectorOr equivalent connector TriggerIn+Vertical Timing Full Scanning Horizontal TimingFixtrig AOI Area of InterestPixel Transferring Image Pulse Width Trigger Mode Normal ModeTiming Trigger signal With Photocoupler delay Exposure Timing with the Positive Polarity Trigger SignalInput Trigger signal Trigger signalEdge Preset Trigger Mode 13/37 14/37 15/37 Reset Mode Communication Method Communication SettingsCommunication Format Name Descriptions 【Example Code】Reading the data from the command 00H Camera Command List Device Code Camera Control Command21/37 22/37 23/37 Underline settings are the factory default settings Descriptions of the Camera Control Commands Device code25/37 26/37 27/37 28/37 29/37 AGC Descriptions of the Camera Commands Device code31/37 32/37 33/37 GenICam command Device Command Function GenICam Command / Camera Command Reference Table2EH 36/37 37/37