Elinchrom BX 250RI, BX 500RI operation manual Flashtube replacementEnglish, Error Management

Page 15

Flashtube replacementEnglish

If the unit does not flash but the ON/OFF switch indicates that there is power, it could be that the flash tube needs replacing. Flash tubes have a long life with average use,

but multiflashing in long sequences can cause overheating of the electrodes leading to premature ageing, or perhaps the flastube is broken or cracked

To replace the flash tube:

1. Switch off the mains switch

2.Remove the mains cable

3.Take the unit from its stand or lay it horizontally on a rigid surface. It will need to be held firmly whilst removing and replacing the tube.

4.Allow the flash tube and modelling lamp to cool for several minutes. They may be very hot.

5.Carefully remove and store the modelling lamp.

6.Use a protective glove to remove the flashtube:

A – Pull the flash tube firmly out of the terminals

B – If the tube is broken, use security gloves. Avoid cutting yourself!

C - If the tube is broken, never touch the metal electrodes and ensure that the unit is disconnected from the mains and discharged, wait min. 30 minutes! Use an insulated tool to pull out the electrodes.

7.Take the new flash tube. A glove or "plastic protection" MUST BE USED. Contact with your fingers on the glas, will cause dark markings on the tube when it is used.

8.Check that the tube is correctly aligned (central) and that the trigger contact is gripping the tube.

9.Re-connect and test the unit as usual.

Error Management

Error

Fault

 

Description

E1

 

Overvoltage

 

Switch unit OFF, wait 2 minutes and switch unit ON again. If the error shows

 

 

 

detected

 

up again the unit requires a check up at the Elinchrom service centre

 

 

 

 

 

E2

 

Overheating

 

Wait until the unit has cooled down. The unit will switch back to normal opera-

 

 

tion as soon as temperature decreases to normal working level.

 

 

 

 

 

 

 

 

 

 

 

 

 

The Unit has detected a time out in the ADF mode. Switch the unit OFF, wait

E3

 

Auto dump

 

2 minutes and switch the unit ON again; use the Test release button for power

 

function fault

 

reduction. If the error shows up again the unit requires a check up at the Elin-

 

 

 

 

chrom service centre.

 

 

 

 

 

 

 

 

 

Unit has detected a time out during recharging. Switch unit OFF, wait

E4

 

Charge fault

 

2 minutes and switch unit ON again. If the error shows up again the unit

 

 

 

 

requires a check up at the Elinchrom service centre.

 

 

 

 

 

 

 

 

 

Unit has detected a mains supply fault. Check your mains cord and mains

E5

 

Mains supply

 

installation sockets. Switch unit OFF, wait 2 minutes and switch unit ON again.

 

fault

 

If the error shows up again the unit requires a check up at the Elinchrom

 

 

 

 

service centre.

 

 

 

 

 

 

 

Fan manage-

 

Unit has detected a FAN management problem due to overheating. Wait until

E8

 

 

the unit has cooled down. Check if the FAN is blocked. If the error shows up

 

ment fault

 

 

 

 

 

again the unit requires a check up at the Elinchrom service centre.

14

Image 15
Contents Page English Table of contentsEnglish CE Statements for EL-Skyport Declaration of conformityDisposal and recycling CE markingTransport Safety NotePower cable Flash tubes and modelling lampsIncluded basic features Mains fuse Switch and fuse Mains supplyBefore you start Operating instructionsControl panel Overview of controls Modelling lamp modes Programmable features ResetHow to „Reset the BX-Ri Setup Visual-Flash-Control VFC modeEye-Cell advanced photocell sensor Digital multi-displaySychronisation socket Open flash «test»Intelligent Photocell-Sensor Eye-CELL SetupUsing the Standard Photocell Mode Automatic Eye-Cell Pre-Flash Setup c.0Manual Eye-Cell Pre-Flash Setup Setup Pre-Flash Timeframe only for advanced usersPre-Flash Timeframe Setting t.X Charge Ready Beep Features Power Steps Per Push EL- Skyport Transceiver For Wireless Triggering SetupGroup Settings Frequency Channel SettingsError Management Flashtube replacementEnglishBX 500Ri Contents Operating Instructions FeaturesBattery Installation Hot-Shoe Connector with Screw-LockFrequency Channel EL-Skyport Sync Speed & Standard ModeIntegrated Hot-Shoe Sync 2.5 mm Socket EL-Skyport Transmitter Speed RX FeaturesEL-Skyport Modules TroubleshootingCE Statements FCC Compliance and Advisory StatementDisposal and recycling