2.To fix the camera position, hold down either hook of the inner cover and lift it up.
3.Push the release lock out while turning the main unit in the <UNLOCK> direction to remove the bracket.
If this doesn't work, use the hole on the bottom of the bracket to turn the bracket in the <LOCK>direction.
4.Use the provided screws (x3) to fix the bracket to a desired position (ceiling or wall).
Ensure that the <CAMERA FRONT> label on the bracket faces the direction for camera monitoring.
5.Arrange the cables through the bracket to the ceiling or wall.
If you drill a hole in the ceiling cover for wiring, press hard to remove the cover and attach the
6.Mount the main unit onto the bracket.
Align the marking hole of the main unit with the | Wiring Cover |
<CAMERA FRONT> label of the bracket, and |
|
turn the unit in the <LOCK> direction. |
|
7.Adjust the lens in a desired direction.
For adjusting the lens direction, refer to "Adjusting the monitoring direction for the camera". (page 31)
8.Secure the inner cover to the main unit.
Fit the two holes of the
9.Fix the cover to the main unit.
Fit the protruding part inside the cover into the corresponding hole of the main unit, and turn the cover to fix it.
M INSTALLATION & CONNECTION
English _25