6.1 Connecting a PC

To connect a PC to the PIP-300unit, using the Null-modem adapter provided with the machine (recommended):

￿￿Connect the RS-232 DB9 rear panel port on the PIP-300unit to the Null-modem adapter and connect the Null-modem adapter with a 9-wire flat cable to the RS-232 DB9 port on your PC

To connect a PC to the PIP-300unit, without using a Null-modem adapter:

￿￿Connect the RS-232 DB9 port on your PC to the RS-232 DB9 rear panel port on the PIP-300unit, as Figure 4 illustrates

PIN 5 Connected to PIN 5 (Ground)

PIN 3 Connected to PIN 2

PIN 2 Connected to PIN 3

Female DB9 (From PC)

Male DB9

PIN 4 Connected to PIN 6

 

PINS 8, 7, 1 Connected together

 

If a Shielded cable is used, connect the shield to PIN 5

 

Figure 4: Connecting a PC without using a Null-modem Adapter

11

Image 14
Contents Models Contents FiguresTables Quick Start IntroductionGetting Started Menu Items PIP-300 and PIP-200xl feature OverviewYour Picture in Picture Inserter Machines Define the Picture in Picture Inserter machinesPIP-200xl Picture in Picture Inserter PIP-300 Picture in Picture Inserter Feature Function Front Panel Picture in Picture Inserter FeaturesRear Panel Picture in Picture Inserter Features Installing on a Rack Before Installing on a RackConnecting the PIP-300 Picture in Picture Inserter Connecting the PIP-300 Picture in Picture Inserter Connecting a PC Connecting a PC without using a Null-modem AdapterPIP-300 Main Menu Items Configuring and Operating your PIP-300Using the Menu Menu Item FunctionPIP-300 Menu Guide Mode Function Mode Submenu FeaturesPIP Sizing and Positioning Features Recommended PIP sizes Video Settings Submenu FeaturesPresets Submenu Features Labeling Submenu Size and position channels 1 and 3 as desired Displaying the Layers in the PIP ModePress Input button 1, or Downloading from the Internet Firmware UpgradeConnecting the PC to the RS-232 Port Upgrading FirmwareAction area, select Erase then Program Technical Specifications PIP-200xl PIP-300Communication Protocol1 Protocol DefinitionsInstruction Codes for the Communication Protocol # Hex DescriptionDetails of Instruction SET Instruction 0x11 Contrast Instruction 0x21 to Instruction 0x29 Labeling Only the first purchase customer may enforce this warranty 2900-000081 REV