Communication Protocol

Table 11: Instruction Codes for the Communication Protocol

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

# (Hex)

Description

BYTE2

 

BYTE3

0x00

Reset

0

0

 

0x01

Active input select

1 to 5 – select input number

0

 

0x02

Mode select

0

0 for single mode (non-PIP)

 

 

 

1 for PIP mode

 

 

 

2 for QUAD

0x03

Store

1 to 0x02 – address for storing

0 to store

 

 

 

1 to erase

0x04

Recall

0 to 0x02 – address to retrieve

0

 

0x09

Video input format

1 to 5 – input number

0

– CV

 

 

 

1

– Y/C

 

 

 

2

– YUV

0x0A

Request video

1 to 5 – input number

1

– NTSC

 

input standard

 

2

– PAL (B,G, H, I)

 

 

 

3

PAL-M

 

 

 

4

PAL-N

 

 

 

5

– NTSC4.43

 

 

 

6

– SECAM

0x0B

Video output

0

1

– NTSC

 

standard

 

2

– PAL (B,G, H, I)

 

 

 

3

PAL-M

 

 

 

4

PAL-N

 

 

 

5

– NTSC4.43

0x10

Error

0

0

 

0x11

Contrast

0

0 to 100

0x12

Saturation

0

0 to 100

0x13

Brightness

0

0 to 100

0x1a

PIP size

1 to 5 – input number

1

– 1:1

 

 

 

2

– 1/4

 

 

 

3

– 1/9

 

 

 

4

– 1/16

0x1b

PIP position: X

1 to 5 – input number

0 to maximum to the right

0x1c

PIP position: Y

1 to 5 – input number

0 to maximum to the bottom

0x1d

Border

0

0

– Off

 

 

 

1

– White border

 

 

 

2

– Black border

0x1e

Freeze

1 to 5 – input number

0

– Normal operation

 

 

 

1

– Frozen

0x21

Label: character 1

1 to 5 – input number

Hex value of ASCII character

0x22

Label: character 2

1 to 5 – input number

Hex value of ASCII character

0x23

Label: character 3

1 to 5 – input number

Hex value of ASCII character

0x24

Label: character 4

1 to 5 – input number

Hex value of ASCII character

0x25

Label: character 5

1 to 5 – input number

Hex value of ASCII character

0x26

Label: character 6

1 to 5 – input number

Hex value of ASCII character

0x27

Label: character 7

1 to 5 – input number

Hex value of ASCII character

0x28

Label: character 8

1 to 5 – input number

Hex value of ASCII character

0x29

Label: character 9

1 to 5 – input number

Hex value of ASCII character

0x31

OSD

0

0

– OSD off

 

 

 

1

– OSD on

0x39

Auto-save

0

0

Auto-save off

 

 

 

1

Auto-save on

0x3d

Identify machine

1

2

– for PIP-200 (reply)

 

 

 

3

– for PIP-300 (reply)

 

 

 

4

– for PIP-400 (reply)

 

 

 

5

– for PIP-500 (reply)

 

 

3

Software version (reply)

 

 

 

 

 

22

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 25
Contents Models Figures ContentsTables Getting Started IntroductionQuick Start Menu Items Overview PIP-300 and PIP-200xl featureDefine the Picture in Picture Inserter machines Your Picture in Picture Inserter MachinesPIP-200xl Picture in Picture Inserter PIP-300 Picture in Picture Inserter Rear Panel Picture in Picture Inserter Features Front Panel Picture in Picture Inserter FeaturesFeature Function Before Installing on a Rack Installing on a RackConnecting the PIP-300 Picture in Picture Inserter Connecting the PIP-300 Picture in Picture Inserter Connecting a PC without using a Null-modem Adapter Connecting a PCUsing the Menu Configuring and Operating your PIP-300PIP-300 Main Menu Items Menu Item FunctionPIP-300 Menu Guide PIP Sizing and Positioning Features Mode Submenu FeaturesMode Function Presets Submenu Features Video Settings Submenu FeaturesRecommended PIP sizes Labeling Submenu Press Input button 1, or Displaying the Layers in the PIP ModeSize and position channels 1 and 3 as desired Connecting the PC to the RS-232 Port Firmware UpgradeDownloading from the Internet Upgrading FirmwareAction area, select Erase then Program PIP-200xl PIP-300 Technical SpecificationsProtocol Definitions Communication Protocol1# Hex Description Instruction Codes for the Communication ProtocolDetails of Instruction SET Instruction 0x11 Contrast Instruction 0x21 to Instruction 0x29 Labeling Only the first purchase customer may enforce this warranty 2900-000081 REV