Toshiba IK-1000 instruction manual Operation, Sens Function

Page 13

6. OPERATION

q Referring to the above item “4. CONNECTION,” connect necessary equipment. w Turn on the connected equipment and the power source of this camera.

e Point the lens at the object, operate the lens iris adjustment, focus adjustment, etc. r Refer to the items “6.1 Sense Function,” “6.2 White Balance,” “6.3 SCENE file” and “7.

MODE SETTING BY ON SCREEN DISPLAY,” select the necessary items and perform the operations.

6.1SENS Function

This unit provides the SENS function to control lens iris and sensitivity, and adjust brightness of video images. The SENS function is divided into the two modes described later: AUTO and MANUAL. Each of them can be used combined with the controls described below.

Lens automatic iris control:

Automatically controls the brightness by the automatic iris lens.

Electronic multiplication (CMG) control:

The electronic multiplication function of EM-CCD (electronic multiplication CCD imaging element) adopted in this camera controls the sensitivity inside the imaging element. This control is characterized by noise lower than the circuit gain (AGC) control and the sensitivity control with residual image far less than long term exposure. This control is optimum with importance placed on the shooting of a moving subject.

Circuit gain (AGC) control:

Controls the sensitivity of EM-CCD imaging element output in a subsequent circuit. We suggest giving the highest possible priority to the electronic multiplication (CMG) control.

Long term exposure control:

Controls the sensitivity of exposure time of EM-CCD imaging element by exposing for a long time in units of two fields.

Though long term exposure (low shutter speed) causes residual image and/or blurring of object, the sensitivity control of a stationary object makes noise lower than the electronic multiplication (CMG) control or circuit gain (AGC) control.

This control is optimum for shooting stationary object with lower noise.

Electronic shutter control:

Sets electronic shutter exposure time to control the sensitivity.

Two modes are available: MANUAL mode in which exposure time can be selected from 1/100s, 1/250s, 1/500s, 1/1000s, and 1/2000s, and Synchro. Scan mode where exposure time can be set in units of horizontal scanning time (1 H) or in units of two fields. This setting can be made in the MANUAL mode only.

-13 -

Image 13
Contents CCD Color Camera Table of ContentsPage Important Safeguards Field Installation Install the camera in a location free from noise On installation, observe the following mattersOperating ambient temperature and humidity Outdoor installationComponents When cleaning the cameraNames and Functions Handling of the protection capPage Setting screens 4Tripod setting hole Connection How to Adjust Iris Lens AdjustmentAvailable Lens Automatic iris lensHow to Adjust Back Focus and field angle Sens Function OperationManual mode Auto ModeONE Push WB One Push White Balance White BalanceManual Manual white balance Scene filesUsing the Screens Mode Setting by on Screen DisplayItems that can be set on screen display When Changing Setting of Auto Sens Mode Sens sensitivity settingChanging flicker correction Page Bold face on the diagram shows a detection area Data UP When Changing Settings of Manual mode Synchro. Scan mode Data UP Increase in red WHT BAL White BalanceDecrease in red Data Down Data UP Increase in blueBold face on the diagram shows a detection area Mode ATW When Changing Settings of Manual Manual White Balance Mode Process Process Option Option Data UP Increase of gain Decrease of gain Data Down Stop of use TroubleshootingExternal View Manu SpecificationsPage Page Page Page Page One 1 Year