7.3.3 When Changing Settings of MANUAL mode (Synchro. Scan mode)
Up/down movement |
| Set by DATA |
by MENU UP/DOWN |
| UP/DOWN |
|
|
|
<FILE A> | |
MODE MANUAL |
|
SHUTTER SS |
|
SYNCRO SCAN | 30FLD |
CMG | OFF |
GAIN | OFF |
LEVEL | 0 |
PEAK/AVE | AVERAGE |
AREA | PRESET A |
・Display of SCENE file |
|
・SENS mode | AUTO, MANUAL |
・Electronic shutter mode | MANUAL, SS |
・Synchro. Scan shutter speed | 9/262.5H, 10/262.5H, …, 255/262.5H, |
| OFF, 2FLD, 4FLD, 6FLD, …, 256FLD |
・Electronic multiplication gain OFF, CMG1, CMG2, …, CMG10 | |
・Circuit gain | OFF, 1dB, 2dB, …, 18dB |
<SENS MODE=MANUAL, SHUTTER MODE=SS>
(1)Changing the setting of Synchro. Scan shutter speed
q Using the [MENU UP] or [MENU DOWN] button, place “→” on SYNCHRO SCAN. w Using the [DATA UP] or [DATA DOWN] button, select the shutter speed.
[DATA UP]
9/262.5H 255/262.5H OFF 2FLD 256FLD
[DATA DOWN] Long term exposure
*Electronic multiplication gain and circuit gain can be set as in the case of MANUAL electronic shutter mode. (Refer to 7.3.2 (2)/(3))
Note
When setting the MANUAL long term exposure, the automatic iris cannot used.
- 24 -