Introduction

Setup decisions for the PARTNER® II Communications System or PARTNER Plus Communications System should be recorded on the forms in this Planner. The forms must be filled out before installation to provide guidance for the technician who installs and programs the system.

The forms should also be used by the customer to record changes after installation, so there is an ongoing record of the programming for the system. If programming is inadvertently erased (for example, in the event of an extended power failure), the forms can be used to reprogram the system.

Identifying a System Manager

As part of the planning process, the customer should identify a person in the company to act as System Manager. The System Manager is the person who is responsible for the telephone system. The System Manager should work with you to fill out the forms, and should participate (with an alternate) in the training for the system. The System Manager can then provide training, answer questions for telephone users, and perform programming for the system after installation.

2.Provide advice to help the customer fill out any additional forms needed for installation.

If button features should be programmed onto users’ telephones cen- trally (instead of letting users do it themselves), the desired button programming should be specified using the appropriate telephone templates or feature checklists on Form C1 through Form C8.

If the customer plans to use dialing restrictions, Form D should be used to specify a list of Emergency Phone numbers that will override restrictions. Form D can also be used to specify lists of Disallowed and Allowed numbers to fine tune the dialing capabilities for individual extensions, to identify External Hotline phones that dial a specified telephone number as soon as the handset is lifted, and to specify up to 99 account codes for account code verification.

If the customer wants System Speed Dial numbers programmed that will be available to all system users, Form E should be filled out.

After the forms are completed, take the original and leave a copy with the customer.

Filling Out Planning Forms for the Customers

The planning forms were designed to be as self explanatory as possible. The first few times you fill out the forms, it may help to refer to the supplemental instructions on the pages that follow. For detailed information about system features, see the PARTNER II or PARTNER Plus Communications System Programming and Use guide.

We suggest you complete the forms as follows:

1 . Fill out Form A (to describe the customer’s overall system configuration) and Form B1 (to record basic information for each system extension).

If you want to customize extension settings for different users, complete Form B2 as well.

NOTE: For system options that require programming, the forms show the name of the procedure and the programming code in the form {#NNN} (for example, Line Assignment {#301}); centralized programming procedures for individual extensions are identified by the letters {CTP} for "Centralized Telephone Programming" (for example, Line Ringing {CTP}).

Customer Training

In the U.S., a Lucent Technologies representative will provide training at the customer’s place of business when the system is installed and programmed. (Outside the U.S., customers should contact their Lucent Technologies Repre- sentative or local Authorized Dealer for information about training.) The repre- sentative will demonstrate how to:

Handle calls and use system features

Program features and phone numbers onto phone buttons

Change the programming for the system and for individual telephones

Use the Quick Reference cards and the Programming and Use guide

To prepare for training, please tell the customer to:

Set aside approximately two hours of uninterrupted time for training on installation day, preferably in a quiet place away from distractions.

Designate one person (generally the System Manager) and an alternate to participate in the training. These persons will then train the rest of the company staff.

This training will ensure that the customer takes maximum advantage of their new Lucent Technologies system. Thank you for your cooperation.

1

Image 3
Contents Release System Planner Contents Customer Training IntroductionIdentifying a System Manager Filling Out Planning Forms for the CustomersForm a Supplemental Instructions System Configuration Configure Hardware for Hybrid ModeSystem Lines VMS-AA System SettingsLine Coverage DXDSmdr Auxiliary Equipment SystemIdentify Auxiliary Equipment Attached to this Extension Form B1 Supplemental Instructions System ExtensionsWrite Name/Description Identify Telephone Attached to this ExtensionLine Ringing CTP Identify Extension Settings if Different from DefaultIdentify Group Assignments Identify Restrictions/PermissionsMLS-34D Telephone MLS-18D, MLS-12D, and MLS-12 Telephones Form C Supplemental Instructions Button TemplatesPartner II system only Intercom AutodialerExample Templates PARTNER-34D Telephone PARTNER-18 TelephonePARTNER-CA48 Intercom Autodialer Button Feature Summary Extension 10 FeaturesAuto Dialing Features Dlpi Dial-Code FeaturesACE DlpaViob LNRSNR TT-ENAllowed Phone Number Lists #407 Form D Supplemental Instructions Number ListsCreating Disallowed and Allowed Lists Disallowed Phone Number Lists #404Important Notices Forced Account Code List #409Emergency Phone Number List #406 External Hotline #311Form E Supplemental Instructions System Speed Dial Numbers General GuidelinesSpecial Dialing Functions Hunt Caller Subscription Services List personalWrite Line Write the TelephoneNight only is desired Is desired Form B1 System Extensions Required for Partner II System extensions 34 through Ext Write Return Jack OtherWrite Name/Description Equipment Character Codes Letters Numbers Letters Numbers Character CodesForm B2 Customized Extension Settings Form B2 Customized Extension Settings Intercom Intercom Check Desired FeaturesForm C1 PARTNER-34D Phone SampleFor additional intructions Partner II only See Form C2 Intercom AutodialerVoice Mailbox Transfer F VMBox Form C3 PARTNER-18 PhoneMS-XX Form C4 PARTNER-6 PhoneForm C5 MLS-34D Phone Identify extensions programmed as shown Form C6 MLS-18 PhoneForm C7 MLS-12 Phone Form C8 MLS-6 Phone Disallowed Phone Number Lists #404 Form D Number ListsForced Account Code List #409 Code Name/Company Form E System Speed Dial NumbersLucent Technologies Issue August