Sony SAL35F14G service manual Adjusting Method

Page 56

2. Adjusting Method

1)Move the preset ring and fix it at the fully opened position.

Set the preset ring at the open aperture position.

Preset lever

Fig.4-2-10

2)Adjust by rotating the iris retainer ring so that the blades of iris are just hidden within the inner diameter of iris retainer ring.

Diaphragm blades are hidden into the edge completely.

Fig.4-2-11

3)After adjustment, apply the adhesive bond (B-10) to portions shown in Fig.4-2-9.

4)Assemble the lens in the state of near completion. Perform “4-2-1. Confirmation of iris diameter”.

Note: Repeat “4-2-2. Adjustment of iris diameter” and “4-2-1. Confirmation of iris diameter” until the iris tolerance meets the specifica- tion.

SAL35F14G (1.4/35G) (35mm F1.4G)

4-17

Image 56
Contents Specifications Disassembly Service Note Repair Parts ListSpecifications Table of Contents Service Note Safety CHECK-OUT Troubleshooting Aperture TroubleFocus Trouble Focus trouble Function NG Position NGDisassembly Exploded View Ornamental Ring Block Outer Tube and Joint Tube Fixed Tube Block and Distance Control Tube Ornamental Ring Block and Focus Hold Button Base GROUP, 2 Group and 3 Group Lens Block Help HELP01HELP02 HELP03 HELP04 HELP05HELP06 HELP07HELP10 HELP08HELP09 HELP11 HELP12 HELP13 HELP14 G7 G8 G9 G10HELP15 HELP16 HELP17 HELP18 HELP19 HELP20 HELP21HELP22 HELP23Repair Parts List Exploded ViewsLens Mount Riveting Block and Light Inter Ception Tube Outer Tube and Joint Tube 151 152 154 155 153 156 157 158 159 160 161 161 163 162 164 165202 203 209 208 204 205 212 213 211 253 255 Ref. No.110 Ref. No.60Ref. No.73 Supplied Accessories Checking supplied accessories Other accessoriesList of Service Tools and Equipments PreparationsChart Mm collimator Equipment used Lens Adjustment Program ActuatorCheckerDownload of PC card setup file InstaCal.exe SAL35F14G 1.4/35G 35mm F1.4G Setup of PC Card SAL35F14G 1.4/35G 35mm F1.4G SAL35F14G 1.4/35G 35mm F1.4G Confirmation of PC card setting Startup of Lens Adjustment Program ActuatorChecker.exe Equipment Finished Inspection JIG LensInitial Setting of ActuatorChecker Model Preparations Aperture Diameter CHECK/ADJUSTMENTAperture Diameter Check Checking of Image Specification Checking MethodAperture Diameter Adjustment Adjusting Method Projective Resolving Power Check Plane mirror Number of the smallest pitched lines Flange Back f’F CHECK/ADJUSTMENT Flange Back f’F CheckOptical Axis Adjustment Frange Back f’F CheckOver Infinity Infinity End Flange Back f’F Adjustment Focus-shift mm = 0 to +0.15 Perform the 4-9. Write dSB Lens ROM Check Click ROM DataCase of error display in the ROM Data Focus Brush Position CHECK/ADJUSTMENT Focus Brush Position Check Search Focus Adjustment PointCase of error display in the Search Focus Adjustment Point Focus Brush Position Check Focus Adjustment Point Click the Focus Adjustment PointCase of error display in the Focus Adjustment Point Focus Brush Pattern CheckFocus Brush Pattern Click the Focus PatternCase of error display in the Focus Pattern near position Case of error display in the Focus Pattern infinity position Focus Hold Button Check Focus Hold Button Click the Focus Hold ButtonCase of error display in the Focus Hold Button Write dSB Case of error in the Write dSB Switching a Application of printingReversing the screens displayed once Finding a textContents Rev Issued Ver