4-4-2. Over Infinity (Infinity End) Flange Back (f’F) Adjustment
Equipment
•1000 mm Collimator
•Flange Back Tester
•
•Flange Back Gauge (43.50mm)
•Adhesive bond
Adjusting Method
1)Perform
2)Adjust the lens focus to the infinite.
3)Observing the microscope, adjust the focus by turning the knob of
4)Calculate the shift amount by formula below.
Shift Amount (x) = f’F (measured value) at infinite - 44.59mm
x:Shift amount to be adjusted by backwasher
5)Depending on the result in step 4), adjust the thickness of backwasher. (Refer to Table
Note: Measure the thickness of backwasher with micrometer or calipers.
•When the shift amount (x) is the positive (+) value: Increase the thickness of backwasher by a value of x.
•When the shift amount (x) is the negative
6)Build in the backwasher and perform
Specification
f’F (mm) | |
f(mm) | (Infinity position) |
|
|
35 | 44.58 to 44.60 |
|
|
Table
7)When the flange back (f’F) is out of specification of the Table
Part No. | Description |