Ver 1.1 2007.02
4-3. PROJECTIVE RESOLVING POWER CHECK
Equipment
•Lens Test Projector and Variable Transformer (Output voltage: AC 100 V)
Note: Connect the variable transformer (Output voltage: AC 100 V) to the lens test projector.
•
•Screen (Art paper)
•Tape Measure
•Plane Mirror (For SLRs)
1. Preparations
Note: Check the projective resolving power of the checking lens at the following
Distance (m) | |
f (mm) |
|
|
|
35 | 1.4 |
|
|
Table
1)Perform the following steps (1) to (3), and incorporate the internal lenses of the lens test projector according to the checking focal- length.
(1)Open the lid of the lens test projector.
(2)Pull up and turn the fixed levers on the right and left sides of the lens test projector.
(3)Remove or insert the lens.
Note: Be sure to have the right position and direction of the lens.
Incorporate of the lenses
according to the checking
Fixed lever | Lens |
Chart
Chart
Filament
Filament
f=18 to 35 mm | f=100 to 200 mm |
Fixed lever
Lid
Chart | Chart |
Filament
Filament
f=35 to 100 mm | f=200 to 300 mm |
Lens test projector