Polaroid SX70 manual Viewfinder, Mirrors, Flare baffle, Camera Elctronics 1. General

Page 18

2. Viewfinder

The viewfinder optics consist of an eye lens, a concave mirror and a wafer lens (Figure 2-4). As in all simple optical system, a certain amount of distortion is inherent in this design. A small wafer lens is introduced into the viewfinder optical path to limit to angle of acceptance and, thus, reduce distortion. The size of the lens opening is large enough to provide acceptable viewing brilliance and, at the same time, small enough to be easily closed when the camera is in the exposure mode. (On earlier models a rectangular mask called a stigmatic pupil takes the place of the wafer lens.

Figure 2-4 Wafer lens assembly

Ignoring the shutter functions momentarily, when the operators presses the exposure button, the Fresnel carrier swings away from the film plane and comes to rest in front of the viewing mirror. During the moment of the Fresnel carrier (and until it returns to its initial viewing position), a flexible light stop closes a path between the viewfinder and the inner camera to prevent light trough the eye lens from reaching the film. The movement of the spring-driven Fresnel carrier is accomplished by the motor-driven gear train. The details of the automated action are described in the discussion of the electro / mechanical assemblies.

3. Mirrors

Two first surface mirrors are used in the SX-70 optical system. When a picture is being taken, the Fresnel carrier is raised. This places the 4-edges taking mirror into the optical path and light is reflected onto the film plane. (The taking mirror is mounted on the Fresnel carrier on the side opposite the Fresnel screen.) The second

mirror, the 6-edges viewing mirror is used in the optical path twice. First, the light rays entering the camera from the taking lens are reflected onto the Fresnel screen by the viewing mirror. Secondly, the operator views the image on the screen with light reflecting off the viewing mirror (Figure 2-1). (The viewing mirror is located on the underside of the mirror cover assembly.)

4. Flare baffle

The flare baffle (Figure 2-2) is a spring-loaded plate which springs up when the Fresnel screen moves into the picture-taking mode. In this state, light is prevented from passing through the lens directly onto the film without first being reflected off the taking mirror. This prevents «hotspots» from appearing on the finished picture. When the Fresnel carrier is in the lowered position, the flare baffle is held down, out of the optical path.

E. CAMERA ELCTRONICS 1. General

The SX-70 is unique, both in its principles of operation and its functional design. It can be considered as aan electronically controlled mechanical device. An electronic control module (substrate or ECM) contains all of the electronic components with the exception of the motor control (MCC) integrated circuit and the flash fire assembly (FFA). Because the ECM is located inside the shutteur housing, it becomes identified as part of the shutter (Figure 2-5). It should be noted that all of the camera automation is controlled by the integrated circuits in the ECM.

Figure 2-5 ECM - Electronic Control Module

Image 18
Contents Page Page Description General DescriptionCamera Operation Opening the CameraLoading the Film pack Starting the Automatic MechanismSetting the exposure counter Viewing and focusingViewing and shooting Exposures using flash Completing the film packDeveloping the print Shutter Description Ambient Light Mode Closing the camera11 a Location & Arrangement of internal parts Shutter Description Flash Mode Page 14 S5 being opened by the recock ram Gear train Page Lens Power Source Introduction Viewing and Exposing SystemFresnel Figures 2-3 a and 2-3 B Viewfinder optics exposingFresnel screen Flare baffle ViewfinderMirrors Camera Elctronics 1. GeneralSwitch functions SX-70 Switch locationsS3 Being opened by recock ram S4 Switch operating configurations Switch Function Table Function SequencePage Flash Timing Sequence Chart Shutter Mechanical Details Figure Shutter, exploded viewA Solenoid S2 operation Film Processing Components Sequence of OperationsPage Max III Troubleshooting Introduction Initial TestsSX-70 Cmaera Repair Inspection Procedure Power supply and pack simulator Figure Test Equipment OperationCollimator Figure Location of new collimator targetDisengaging the idler gear Comprehensive Testers -6 Comprehensive testerModel B Camera tester Model B Camera Tester Comparalumen Light Levels Table Light Leak Tester FigureFlash Simulator Board Figure Light leak test systemManual Function Tester Figure 10 Manual camera testerManual Function Test Sequence Optical System Exit Pupil TestEntrance Pupil Test 13 Aligning the exit pupil gageFresnel Quality Check USE of Analysis ChartsConcave Mirror Distortion Check Collimation16 Fresnel standards chart Camera/Shutter Isolation 18 Flex circuit terminal locationsCamera Analysis Charts 19 Test points on SX-70 shuttersPage Front COVER/SPREAD Roll Assembly InstallationRemoval Repairs / Adjsutments Loose Front Covers Front cover hinge studsBending the stop latch Interference Between Front and Bottom Covers Top Spread Roll LoosenessReplacing the Light Shield Cam Mirror Cover / Boot Assembly Front cover light shield camBoot retaining screws