Specifications

LAN standard

IEEE802.3, IEEE802.3u

 

 

Communication protocol

TCP/IP, UDP, HTTP, FTP, ICMP, ARP, RTP, RTSP, DHCP,

 

NTP

 

 

Monitor output

Composite video x 1 (75 Ω, 1 Vp-p)

Image pickup device

1/3 type IT CCD

Available pixels

Approx. 380,000 pixels (768 (H) x 494 (V))

Video S/N ratio

50 dB (50 %, AGC OFF, Compression rate: 1)

Minimum required illumination

2.5 lx (50 %, F1.2, AGC ON)

Image compression

JPEG, MPEG4

Output image format

640 x 480, 320 x 240, 160 x 120

 

640 x 480 not available for MPEG4

 

 

Lens mount

C/CS mount

Alarm input

Non-voltage ÒAÓ contact input. NPN open collector input.

 

Low level, latch/momentary (500 ms minimum)

 

Low level circuit current: 0.6 mA

 

High level impressed voltage: 3.3 V

 

 

Alarm output

NPN open collector output (allowable impressed voltage:

 

12 V, allowable input current: 300 mA)

 

 

Network interfaces

RJ-45 (Category 5)

 

10BASE-T/100BASE-TX (Auto-Negotiation)

Internal memory

8 MB

Power supply voltage

DC 12 V or AC 24 V, 50 Hz/60 Hz

Power consumption

1.2 A max.

Operating temperature

0 ¡C to 40 ¡C

Mass

Approx. 560 g

External Dimensions

(Unit: mm)

U1-32

 

 

70

 

55

64.5

 

 

35

 

42

 

71

148

138

MAC address

BF LOCK

1/4 – 20UNC

41

Design and specifications are subject to change without notice.

31

Image 31
Contents VN-C11 Important Safeguards Information for USA Safety PrecautionsInformation for Europe Contents Introduction Preparations Operations Others Introduction FeaturesItems Included Upgrading the Application LAN SpecificationsOperating Precautions Bracket for camera mounting Back-focus adjustment ringLens mount BF Lock locking screwSide and rear views Peer-to-Peer Connection PreparationsConnection Examples LAN Connection Network ConnectionOperations with V.Networks Controller Setting the NetworkAdjusting the Camera Setting with V.Networks ControllerAttaching a Lens Preparations Connection and InstallationPin Plug For a system with multiple VN-C11s Power CordPower Monitor OUT Fall Prevention Securing wireInstalling Codec Preparations Setting the NetworkInstalling V.Networks Setup Tool Installing DirectX 8.1 and CodecClick Click in Local Area Connection Properties Preparations Setting the NetworkSelect Settings and click Control Panel Preparations Setting the Network Setting the IP Address for VN-C11 with V.Networks Setup Tool Start up V.Networks Controller. New is displayed Registering the Connected Camera with V.Networks ControllerFor a fixed-focus lens Preparations Adjusting the CameraFor a zoom lens Operations Setting with V.Networks Controller View File SettingHelp Camera Reduced screenPC must also satisfy the following Web browser conditions Operations Operations with a Web BrowserSecurity level User Operator AdministratorVN-C11 top page appears Start up the Web browserExternal Dimensions SpecificationsOthers VN-C11 V.NETWORKS