JVC GY-DV550U instruction manual Left Side Section

Page 18

2. CONTROLS, INDICATORS AND CONNECTORS

2-3 Left Side Section

 

PUSH

q

!0

w

e

DV CAMCORDER

VTR/RM

GY-DV550

PROMPTER

OUTPUT

 

 

 

GENLOCK/AUX IN

Y/C OUT MONITOR OUT

LINE OUT

VIDEO OUT

 

CH-1

CH-2

 

 

 

REMOTE

 

 

 

AUDIO IN

TC IN

TC OUT

 

FRONT

 

LENS

 

 

 

o i u

1 Cassette cover

r t y

 

Pressing the EJECT switch on top of the section opens this cover so that a videocassette can be inserted or removed from the unit. The cover can be locked automatically by pushing and closing it.

If the cassette cover is not closed, the GY-DV550 will remain inoperative.

Memo:

To prevent penetration of foreign objects into the unit, do not leave the unit with the cassette cover open.

2[MONITOR OUT] monitor output connector (BNC)

Connector for composite video signal output. The following video signals are outputted.

E-E video or playback video of VCR

Screen mixed with characters.

External video signal (When VTR INPUT switch is set to AUX) Select whether to output the E-E video/playback video of VCR or character-mixed screen by CHARACTER MIX of the Camera Setup screen. See page 83

Memo:

Select whether to output signals that include setup in the E-E video in SETUP of the Camera Setup screen. See page 83

*Setup is not included during E-E of IEEE1394.

VITC time code is not outputted from this connector.

3[Y/C OUT] connector (4P)

Separate YC video signal output connector.

4[TC IN] connector (BNC)

Input connector for the SMPTE-standard LTC signal. The built-in time code generator can be slave-locked with the input time codes. If the user’s bits should also be slave-locked, set the VCR Setup Menu item No. 403 U-BIT SLAVE to “TC&UB”.

*When the TC GENE switch (& on page 15) is set to REC or REGEN, or the VCR Setup Menu item No. 398 SSF MODE is set to “CUE MODE” or “MARK MODE”, slave-locking will not take place. For the slave lock of time code, see page 64.

5TC OUT connector (BNC)

Output connector for the LTC signal from the built-in time code generator.

The time code recorded on the tape is not output in play mode.

6[LINE OUT CH-1/CH-2] connector (RCA)

Output connector for audio signals.

Outputs the input audio signal in the record and stop modes.

Outputs the playback audio signal in the playback mode.

Alarm sound is not output.

7[VIDEO OUT] Video output connector (BNC)

Connector for composite video signal output.

Camera images are constantly outputted as through images. Camera images are outputted even during external video signal input (when VTR INPUT switch 9 on page 15 is set to AUX).

Whether to output signals with setup can be selected in SETUP of the Camera Setup screen. See page 83

8[GENLOCK/AUX IN] Generationlock/Aux signal input connector

Synchronous signals (black burst signals) are inputted when the GY-DV550’s camera image is synchronized with an external component. Composite video signals are inputted when recording video signals from an external device with this unit. Which video signals to input can be selected using the VTR INPUT switch on page 15.

Memo:

Video signals from this connector are not outputted to the VTR/RM multi-pin connector 8 on page 21.

When the camera remote control unit is connected

with setting the MODE switch 6 on page 20 to RM, this connector will be used for synchronous signal input regardless of the VTR INPUT switch setting.

The camera cannot be synchronized with a VCR playback signal.

When the power is switched ON while an external sync signal is input, the screen moves in a vertical direction for a few seconds. this is not a malfunction.

If the external sync signal is disrupted during recording, the “SYnc inh” (SYNC INHIBIT) indicator is displayed on the counter display and recording stops.

If the external sync signal is disrupted during playback, playback of the disturbed video image continues. Start playback again after synchronization is obtained and the signal is stabilized.

The screen will distort when inputting sync signals to both the main unit and camera remote control unit.

This external video signal input (AUX IN) connector is an auxiliary connector. The bandwidth of Y signals will be 6.75 MHz (8 bit) regardless of the inputted signal bandwidth.

9[REMOTE] connector

A part of the unit's functions can be controlled externally. For connecting the local remote control unit (RM-LP55/RM- LP-57), nonlinear editing device, etc.

When connecting the local remote control unit, Set VTR Setup menu No. 050 REMOTE SELECT to LOCAL or IEEE1394.

When connecting a nonlinear editing device, set to IEEE1394+RS232C.

For details, please consult your JVC dealer.

Note:

If you make an error in the setting, disconnect the connector cable before performing setting again.

0Microphone attachment holes

For attaching the microphone holder KA-A50 (optional).

See "Attaching the Microphone (optional)" on page 34.

18

Image 18
Contents For Customer Use SC96999-002Important Safeguards Information RemarqueRating plate serial number plate is on the top frame Main Features Playback Procedure Fast-Forward, Rewind Search Main FeaturesCamera Settings 10. S.S.F. Super Scene Finder FunctionMain Unit Configuration IntroductionPrecautions for Proper Use Routine and Periodical Maintenance Precautions for Use of Head Cleaning TapeTime management Videocassette to be Used Battery Pack to be UsedCharacteristic CCD Phenomena CondensationCONTROLS, Indicators and Connectors Front SectionTake button Filter Color temperature conversion filter control knobFront Section Cont’d Lens mounting ring/Lens lock leverRight Side Section Right Side Section Cont’d VCR Setting Section Right Side Section Contd Time Code Generator setting switches VCR Display Section Counter display # Tape transport direction indicators$ Remaining Battery Power Display Section for time code related indicationsLeft Side Section Top Section Adapter Section VTR/RM VTR/RM multi-pin connector 26P Prompter Output prompter output connectorRear Section Rear Section Contd Counter Display Contents Lens optional S14 x 7.3B121.5-Inch Viewfinder optional VF-P115BIndications in Viewfinder Batt battery lampREC/ALARM lamp Viewfinder Screen DisplayStatus Switch Event Display ContentsIndications in Viewfinder Contd Display Position FunctionIndication Indication Contents  Alarm Message Display  Time/Date DisplayIndication in Viewfinder Contd  Safety Zone Setting the Screen Display  Auto White Balance DisplayBasic System Connections and Adjustments Basic SystemSliding Securing ring Attaching the Zoom Lens optionalAttaching the Viewfinder optional Stopper screwProvided Microphone Attaching the Microphone providedAttaching the Microphone optional  Attaching the Microphone with KA-A50Attaching the Tripod Base provided Attaching the 4-inch Viewfinder OptionalTripod mounting holes  How to Install the Lithium Battery Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Remove Lithium Batteries Flat shape type battery pack  Anton-Bauer battery pack Power SupplyBattery Pack Operation AC OperationBattery Pack Operation Contd Attaching a Flat Shape Type Battery PackAttaching the Battery Pack Using AN ANTON-BAUER Battery PackAttaching and Detaching an Anton-Bauer Battery Pack Detaching the Battery PackOperating Time with Battery Pack Remaining Battery Power DisplayPrecautions for the Battery Pack Battery Pack Continuous Operating Time at 25 ˚CTurning the Power on VTR switch setting GY-DV550 operation modePreparations REC Save Stby VTR switch Switch on Back of VideocassetteCassette Loading and Unloading REC INHSetting the Date and Time Time display Counter switch TCDate display Counter switch UB Power on Camera SettingsScreen Size 43/169 aspect ratio Mode Selection FilterBrightness and contrast adjustment Viewfinder AdjustmentExternal Monitor Adjustment Eyepiece Eyepiece focusing ringBack Focus Adjustment Accu Focus can also be used in the above stepWhite Balance Adjustment White Balance AdjustmentMixing Characters to Monitor OUT Color video monitorSwitch Settings of the VCR Section  Selecting the CH-2 channel input sound Audio Input Signal Selection Selecting the CH-1 channel input sound Reference input level is +4 dBsIndicator level reference Audio Input Level AdjustmentViewfinder Status 1 Mode For each audio inputMonitoring Audio during Recording Alarm MonitorMonitor Select switch ControlShooting Operation Set the switches as requiredWHT-BAL a or B Set the Iris switch of the lens to a Basic Recording OperationAbout the Quick REC Start Mode Basic Recording Operation ContdRecording from the Save mode VCR Save ModeIf Unit is Left in Record-Pause Standby Mode VTR switch settingRET button Recording External Video Signals GENLOCK/AUXMemo  About the status screen display of the viewfinder Connecting VCR Connecting cable Model Connector Power switch VTR/RM multi-pin VTR Select switch ConnectorVTR Input switch Recording with an External VCRAbout the external VCR alarm display VTR Select switch VTR switch Operate switchRecording with an External VCR Contd To stop playback, press the Stop button Playback ModePlayback Procedure Eject buttonFast-Forward, Rewind SearchREW button FF button  Setting the VCR Setup Menu Presetting and Recording of Time Code Setting the time code related switches Time Code OperationPresetting Users BIT Data Presetting and Recording of Time Code Cont’dTime Code Presetting Procedure Advance PresetMulti-Camcorder Master-Slave Connection  Set the related VCR Setup MenusREF Video signal External time code generatorReproducing Time Codes  Reproducing time codes Press the Play button Mark Mode Explanation of the S.S.F. FunctionMemory Take button How to Use the S.S.F. FunctionMark mode Number of memorized scenes VTR trigger buttonDeleting S.S.F. Data Resetting S.S.F. DataReset button LOG button Stop buttonOutputting S.S.F. Data Precautions when writing S.S.F. dataWriting S.S.F. Data to Tape About the Scene End Cue Up FunctionUsing External Components Connecting a Video Component with DV ConnectorFF FWD search is possible REW REV search is possible OUT Connecting a PCMonitor Audio VideoVCR Setup Menu Configuration Setup MenuVCR Setup Menu VCR Setup Menu Group NameVCR Setup Menu Contd Displaying and Setting VCR Setup MenusVCR Setup Menu Contents Setting Factory Group Value Contents Time CodeScreen Camera Menu Screen Flow Camera Menu Screen FlowScene File OFF Status button Shutter dial How to Select from the Camera MenuItemSetting value Normal screen returns in the viewfinderVF Display Screen Operation Screen Process Screen Skin Color Adjust Screen Advanced Process ScreenFile Manage Screen Storage OperationStatus button Setup Screen Time Date screen Resetting of Camera Menu Setting Values Reset OperationER dial Features of the Camera Section WHT.BAL selector switchFull-Time Auto White Balance FAW Iris Brightness Adjustment Adjustment of Lens IrisZebra Pattern Display During Manual Adjustment Band Video monitor Shooting the Screen Image on a Computer Monitor Variable Scan V.SCAN Basic operationSwitch Position Factory-Set Gain Gain Sensitivity AdjustmentGain Switching Gain Boost Under Lolux Condition Automatic Setting Contents Switch Setup According to Illumination and SubjectSwitch Functions Full Auto Shooting FAS FunctionShutter dial 1. Status button How to Use Skin Tone DetailSkin Color Adjust screen Process screenStatus How to Use Skin Tone Detail Cont’d Using the Skin Tone Detail Function DisplayRM-LP57 Shutter EEI setting Gain ALC setting Connecting the Local Remote Control Unit RM-LP55/RM-LP57Zoom Focus SC Coarse SC Fine Phase Gamma Title Title SET SC Coarse SC Fine PhaseHeadset Camera remote control unit Connecting the camera remote control unitVTR/RM connector Back Tally lampRemote control unit Light on Call signals of camera Red Connecting the camera remote control unit Cont’dRemote control unit Light on Tally signals of camera Red RM-P200 Auto SET Nega RM-P300 Auto SET/BLACK Nega ABLOthers TroubleshootingAlarm Indications ServoTroubleshooting Contd VTR Warning ServoBatt VTR Warning Stop VTR Warning HeadVTR Warning DEW VTR Warning HardEarphone AlarmAlarm Tone Display GY-DV550 Operation Auto OFFTroubles with Error Code Outputs Error Code Error Details GY-DV550 Operation RemedyOpen the cassette cover by using Troubles Without Error Code Outputs Symptoms RemedyDoesnt work If so, set to Enable Hour Meter Display Specifications External Dimensions unit mm 140GY-DV550DV Camcorder