JVC GY-DV550U Presetting and Recording of Time Code Cont’d, Time Code Presetting Procedure

Page 63

9. TIME CODE OPERATION

9-2 Presetting and Recording of Time Code (Cont’d)

TIME CODE PRESETTING PROCEDURE

 

2. HOLD button

 

 

4. SHIFT button

CH-1

AUDIO

CH-2

 

 

 

 

LEVEL

 

 

 

 

 

CH-1

CH-2

 

CH-1

CH-2

 

 

 

 

 

 

AUTO

 

FRONT

 

 

 

MANUAL

 

REAR

 

 

AUDIO SELECT

 

AUDIO INPUT

 

 

VTR SELECT TC GENE.

 

MENU

SEE

 

INT

 

CONTINUE

INSTR-

 

PRST

REC

 

 

UCTION

 

PARA

FREE

 

 

 

REGEN

 

 

MANUAL

 

EXT

 

 

 

 

LITHIUM BATT.

CAM AUX

GROUP

ITEM

SELECT

DATA SET

 

 

HOLD

SHIFT

ADVANCE PRESET

 

 

 

 

 

VTR INPUT

 

 

 

 

 

 

3. ADVANCE

 

6.

 

 

 

PRESET

 

 

 

button

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

 

 

 

 

 

HOLD

 

 

H

M

S

 

F

1. Display the time code on the counter display. Set the COUNTER switch to "TC".

Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be preset.

2.Place the time code generator in preset mode. Press the HOLD button.

The "HOLD" indicator lights on the display to indicate the preset mode. The first digit of the counter display blinks.

3.Set the value of the blinking digit. Press the ADVANCE button.

The value of the blinking digit changes.

4.Change the blinking digit. Press the SHIFT button.

The blinking digit changes.

5.Set the desired value for all digits. Repeat steps 3. and 4. for each digit.

6.Preset the set data in the memory. Press the PRESET button.

The set data is saved as the time code generator value. Following the above operation, the "HOLD" indicator disappears from the display, the counter stops blinking and the time code is preset.

If the REC/FREE switch is set to FREE, the time code starts to run.

If you preset a wrong time code, perform steps 2. 3. 4. 5. and 6. again.

PRESETTING USER'S BIT DATA

RESET button

 

OPERATE/WARNING

 

 

 

 

 

 

 

 

CH 1

 

 

OVER

AUTO OFF

DEW

LIGHT

RESET

 

 

ON

 

40 30 20

10

0 dB

SERVO RF

L i

 

CH 2

 

 

OVER

OFF

 

32k

48k

SLAVE

PB

NDF

HOLD

 

MONITOR

AUD LOCK

SP

 

 

 

 

 

 

 

SELECT

MENU

WIDE

H

M

 

S

 

F

COUNTER

CH-1

REMAIN

 

REV FWD

E BATT

F

CTL

MIX

 

TC

 

 

 

 

 

 

CH-2

 

H

M

 

 

 

 

 

UB

Pressing the RESET button in the preset mode resets the time code or user's bit data to 00 00 00 00.

If you press the HOLD button by mistake, press the HOLD button once more to return to the previous display.

Display user's bit data on the counter display and perform the same procedure as the time code presetting procedure.

The user's bit can be specified using numerals or alphabetic letters from 0 to F for each digit.

Note:

Do not set “F” to all user’s bit, or the data can not be read.

63

Image 63
Contents SC96999-002 For Customer UseImportant Safeguards Information RemarqueRating plate serial number plate is on the top frame Main Features 10. S.S.F. Super Scene Finder Function Main FeaturesCamera Settings Playback Procedure Fast-Forward, Rewind SearchIntroduction Main Unit ConfigurationPrecautions for Proper Use Routine and Periodical Maintenance Precautions for Use of Head Cleaning TapeTime management Condensation Battery Pack to be UsedCharacteristic CCD Phenomena Videocassette to be UsedFront Section CONTROLS, Indicators and ConnectorsLens mounting ring/Lens lock lever Filter Color temperature conversion filter control knobFront Section Cont’d Take buttonRight Side Section Right Side Section Cont’d Right Side Section Contd VCR Setting SectionTime Code Generator setting switches VCR Display Section Section for time code related indications # Tape transport direction indicators$ Remaining Battery Power Display Counter displayLeft Side Section Top Section Adapter Section Prompter Output prompter output connector VTR/RM VTR/RM multi-pin connector 26PRear Section Rear Section Contd Counter Display Contents S14 x 7.3B12 Lens optionalVF-P115B 1.5-Inch Viewfinder optionalViewfinder Screen Display Batt battery lampREC/ALARM lamp Indications in ViewfinderDisplay Position Function Switch Event Display ContentsIndications in Viewfinder Contd StatusIndication Indication Contents  Time/Date Display  Alarm Message Display Auto White Balance Display  Safety Zone Setting the Screen Display Indication in Viewfinder ContdBasic System Basic System Connections and AdjustmentsStopper screw Attaching the Zoom Lens optionalAttaching the Viewfinder optional Sliding Securing ring Attaching the Microphone with KA-A50 Attaching the Microphone providedAttaching the Microphone optional Provided MicrophoneAttaching the Tripod Base provided Attaching the 4-inch Viewfinder OptionalTripod mounting holes  How to Remove Lithium Batteries Inserting and Replacing Backup Lithium BatteriesLithium battery CR2032  How to Install the Lithium BatteryAC Operation Power SupplyBattery Pack Operation  Flat shape type battery pack  Anton-Bauer battery packAttaching a Flat Shape Type Battery Pack Battery Pack Operation ContdDetaching the Battery Pack Using AN ANTON-BAUER Battery PackAttaching and Detaching an Anton-Bauer Battery Pack Attaching the Battery PackBattery Pack Continuous Operating Time at 25 ˚C Remaining Battery Power DisplayPrecautions for the Battery Pack Operating Time with Battery PackTurning the Power on VTR switch setting GY-DV550 operation modePreparations REC INH VTR switch Switch on Back of VideocassetteCassette Loading and Unloading REC Save StbySetting the Date and Time Time display Counter switch TCDate display Counter switch UB Filter Camera SettingsScreen Size 43/169 aspect ratio Mode Selection Power onEyepiece Eyepiece focusing ring Viewfinder AdjustmentExternal Monitor Adjustment Brightness and contrast adjustmentAccu Focus can also be used in the above step Back Focus AdjustmentWhite Balance Adjustment White Balance AdjustmentColor video monitor Mixing Characters to Monitor OUTSwitch Settings of the VCR Section Reference input level is +4 dBs Audio Input Signal Selection Selecting the CH-1 channel input sound  Selecting the CH-2 channel input soundFor each audio input Audio Input Level AdjustmentViewfinder Status 1 Mode Indicator level referenceControl Alarm MonitorMonitor Select switch Monitoring Audio during RecordingBasic Recording Operation Set the switches as requiredWHT-BAL a or B Set the Iris switch of the lens to a Shooting OperationBasic Recording Operation Contd About the Quick REC Start ModeVTR switch setting VCR Save ModeIf Unit is Left in Record-Pause Standby Mode Recording from the Save modeRET button Recording External Video Signals GENLOCK/AUXMemo  About the status screen display of the viewfinder Recording with an External VCR Power switch VTR/RM multi-pin VTR Select switch ConnectorVTR Input switch Connecting VCR Connecting cable Model ConnectorAbout the external VCR alarm display VTR Select switch VTR switch Operate switchRecording with an External VCR Contd Eject button Playback Mode Playback Procedure To stop playback, press the Stop buttonFast-Forward, Rewind SearchREW button FF button Time Code Operation Presetting and Recording of Time Code Setting the time code related switches  Setting the VCR Setup MenuAdvance Preset Presetting and Recording of Time Code Cont’dTime Code Presetting Procedure Presetting Users BIT DataExternal time code generator  Set the related VCR Setup MenusREF Video signal Multi-Camcorder Master-Slave Connection Reproducing time codes Press the Play button Reproducing Time Codes Mark Mode Explanation of the S.S.F. FunctionMemory VTR trigger button How to Use the S.S.F. FunctionMark mode Number of memorized scenes Take buttonLOG button Stop button Resetting S.S.F. DataReset button Deleting S.S.F. DataAbout the Scene End Cue Up Function Precautions when writing S.S.F. dataWriting S.S.F. Data to Tape Outputting S.S.F. DataUsing External Components Connecting a Video Component with DV ConnectorFF FWD search is possible REW REV search is possible Video Connecting a PCMonitor Audio OUTVCR Setup Menu Group Name Setup MenuVCR Setup Menu VCR Setup Menu ConfigurationDisplaying and Setting VCR Setup Menus VCR Setup Menu ContdVCR Setup Menu Contents Setting Factory Group Value Contents Time CodeScreen Camera Menu Screen Flow Camera Menu Screen FlowScene File OFF Normal screen returns in the viewfinder How to Select from the Camera MenuItemSetting value Status button Shutter dialVF Display Screen Operation Screen Process Screen Advanced Process Screen Skin Color Adjust ScreenFile Manage Screen Storage OperationStatus button Setup Screen Time Date screen Resetting of Camera Menu Setting Values Reset OperationER dial Features of the Camera Section WHT.BAL selector switchFull-Time Auto White Balance FAW Iris Brightness Adjustment Adjustment of Lens IrisZebra Pattern Display During Manual Adjustment Basic operation Shooting the Screen Image on a Computer Monitor Variable Scan V.SCAN Band Video monitorGain Boost Under Lolux Condition Gain Sensitivity AdjustmentGain Switching Switch Position Factory-Set GainFull Auto Shooting FAS Function Switch Setup According to Illumination and SubjectSwitch Functions  Automatic Setting ContentsProcess screen How to Use Skin Tone DetailSkin Color Adjust screen Shutter dial 1. Status buttonDisplay How to Use Skin Tone Detail Cont’d Using the Skin Tone Detail Function StatusSC Coarse SC Fine Phase Connecting the Local Remote Control Unit RM-LP55/RM-LP57Zoom Focus SC Coarse SC Fine Phase Gamma Title Title SET RM-LP57 Shutter EEI setting Gain ALC settingBack Tally lamp Connecting the camera remote control unitVTR/RM connector Headset Camera remote control unitRM-P200 Auto SET Nega RM-P300 Auto SET/BLACK Nega ABL Connecting the camera remote control unit Cont’dRemote control unit Light on Tally signals of camera Red Remote control unit Light on Call signals of camera RedServo TroubleshootingAlarm Indications OthersTroubleshooting Contd VTR Warning ServoBatt VTR Warning Hard VTR Warning HeadVTR Warning DEW VTR Warning StopAuto OFF AlarmAlarm Tone Display GY-DV550 Operation EarphoneTroubles with Error Code Outputs Error Code Error Details GY-DV550 Operation RemedyOpen the cassette cover by using Troubles Without Error Code Outputs Symptoms RemedyDoesnt work If so, set to Enable Hour Meter Display Specifications 140 External Dimensions unit mmGY-DV550DV Camcorder